{"product_id":"whisperkool-blow-through-8000-he-220v-split-wine-cellar-cooling-system","title":"WhisperKOOL Blow-Through 8000 H.E. 220V Split Wine Cellar Cooling System","description":"\u003cstyle\u003e\n.wce-product-page{max-width:1180px;margin:0 auto;color:#2b2b2b;font-family:Arial,Helvetica,sans-serif;line-height:1.7}.wce-product-page *{box-sizing:border-box}.wce-product-page\u003esection,.wce-product-header{padding:36px 38px;background:#fff}.wce-product-page hr{border:0;border-top:1px solid #e4e4e5;margin:0}.wce-product-header{background:linear-gradient(135deg,#f8f7f4 0%,#fff 70%);border:1px solid #e4e4e5;border-radius:18px 18px 0 0}.wce-eyebrow{display:inline-block;margin:0 0 12px;padding:6px 11px;border-radius:999px;background:#300b05;color:#fff;font-size:12px;font-weight:800;letter-spacing:.08em;text-transform:uppercase}.wce-product-page h1,.wce-product-page h2,.wce-product-page h3{color:#300b05;line-height:1.25}.wce-product-page h2{font-size:30px;margin:0 0 16px}.wce-product-page h3{font-size:19px;margin:24px 0 8px}.wce-product-intro{font-size:18px;line-height:1.75}.wce-stats{display:grid;grid-template-columns:repeat(4,1fr);gap:12px;margin:24px 0}.wce-stat{background:#300b05;border-radius:14px;padding:18px;text-align:center}.wce-stat-num{color:#c8a24a;font-size:28px;font-weight:800;line-height:1.1}.wce-stat-num small{font-size:14px;color:#fff}.wce-stat-lab{color:#fff;font-size:12px;margin-top:8px}.wce-important-notice,.wce-warning-notice,.wce-danger-notice{padding:17px 20px;border-radius:14px;margin:18px 0}.wce-important-notice{background:#f7f8ef;border:1px solid #a3bd04;border-left:5px solid #a3bd04}.wce-warning-notice{background:#fff8e8;border:1px solid #c8a24a;border-left:5px solid #c8a24a}.wce-danger-notice{background:#fff1f0;border:1px solid #9d2d20;border-left:5px solid #9d2d20}.wce-summary-grid,.wce-feature-grid,.wce-buyer-grid{display:grid;grid-template-columns:repeat(2,1fr);gap:14px;margin:18px 0}.wce-summary-item,.wce-feature-card,.wce-buyer-card{background:#f6f6f7;border:1px solid #e4e4e5;border-radius:14px;padding:20px}.wce-summary-item h3,.wce-feature-card h3,.wce-buyer-card h3{margin-top:0}.wce-table-wrap{width:100%;overflow-x:auto;border-radius:14px;border:1px solid #e4e4e5;margin:16px 0 4px}.wce-product-page table{width:100%;border-collapse:collapse;background:#fff}.wce-product-page thead th{background:#300b05;color:#fff;text-align:left;font-size:12px;letter-spacing:.04em;text-transform:uppercase;padding:14px 18px}.wce-product-page tbody th,.wce-product-page td{padding:14px 18px;border-bottom:1px solid #e4e4e5;font-size:14px;vertical-align:top;text-align:left}.wce-product-page tbody th{color:#300b05;width:36%;font-weight:700;border-right:1px solid #e4e4e5}.wce-product-page tbody tr:nth-child(odd){background:#f6f6f7}.wce-product-page tr:last-child td,.wce-product-page tr:last-child th{border-bottom:none}.wce-product-page ul,.wce-product-page ol{margin:10px 0 16px;padding-left:24px}.wce-product-page li{margin:7px 0}.wce-product-page section\u003eh3{padding-left:14px;border-left:4px solid #a3bd04}.wce-resources ul{list-style:none;padding:0;margin:18px 0 0;display:grid;grid-template-columns:1fr 1fr;gap:10px}.wce-resources li{margin:0}.wce-resources a{display:flex;align-items:center;min-height:58px;background:#fff;border:1px solid #e4e4e5;border-radius:10px;padding:13px 16px;color:#300b05;text-decoration:none;font-weight:700;font-size:14px}.wce-resources a:before{content:\"↓\";display:inline-flex;align-items:center;justify-content:center;width:34px;height:34px;margin-right:12px;border-radius:9px;background:#300b05;color:#c8a24a;font-size:18px;flex:none}.wce-faq-item{background:#fff;border:1px solid #e4e4e5;border-radius:14px;margin-bottom:10px;overflow:hidden}.wce-faq-item summary{cursor:pointer;list-style:none;padding:16px 52px 16px 20px;font-weight:700;color:#300b05;position:relative;background:#f6f6f7}.wce-faq-item summary::-webkit-details-marker{display:none}.wce-faq-item summary:after{content:\"+\";position:absolute;right:18px;top:50%;transform:translateY(-50%);width:26px;height:26px;line-height:26px;text-align:center;border-radius:50%;background:#300b05;color:#fff}.wce-faq-item[open] summary{background:#300b05;color:#fff}.wce-faq-item[open] summary:after{content:\"−\";background:#c8a24a;color:#300b05}.wce-faq-body{padding:16px 20px}.wce-faq-body p{margin:0}.wce-final-guidance{background:#300b05!important;color:#fff;border-radius:0 0 18px 18px;margin:0;position:relative;overflow:hidden;text-align:center;padding:42px!important}.wce-final-guidance:before{content:\"\";position:absolute;left:0;top:0;width:100%;height:6px;background:linear-gradient(90deg,#c8a24a,#a3bd04,#c8a24a)}.wce-final-guidance .wce-eyebrow{background:#c8a24a;color:#300b05}.wce-final-guidance h2{color:#fff}.wce-final-guidance p{color:#e8cf93;max-width:820px;margin:0 auto 14px}.wce-product-page a{color:#5a1a0e}.wce-product-page strong{color:#300b05}.wce-final-guidance strong{color:#fff}.wce-specification-disclaimer{font-size:13px;color:#666;font-style:italic}.wce-best-for,.wce-ai-summary,.wce-quick-specifications,.wce-features,.wce-airflow-configurations,.wce-ducting-guidance,.wce-cooling-capacity,.wce-sizing,.wce-technical-specifications,.wce-controller-options,.wce-installation-requirements,.wce-included,.wce-optional-addons,.wce-maintenance,.wce-warranty,.wce-resources,.wce-faq{border-left:1px solid #e4e4e5;border-right:1px solid #e4e4e5}.wce-not-recommended,.wce-airflow-warning{background:#fff;border:1px solid #e4e4e5!important;border-left:5px solid #c8a24a!important;border-radius:16px;margin:18px 0}.wce-positive{border-left:5px solid #a3bd04}.wce-negative{border-left:5px solid #c8a24a}@media(max-width:860px){.wce-stats{grid-template-columns:1fr 1fr}.wce-summary-grid,.wce-feature-grid,.wce-buyer-grid{grid-template-columns:1fr}.wce-resources ul{grid-template-columns:1fr}.wce-product-page\u003esection,.wce-product-header{padding:28px 22px}}@media(max-width:560px){.wce-stats{grid-template-columns:1fr}.wce-product-page h2{font-size:24px}.wce-product-page tbody th,.wce-product-page td{padding:12px 13px}.wce-final-guidance{padding:34px 20px!important}}\n\u003c\/style\u003e\n\u003csection class=\"wce-product-page\"\u003e\u003cheader class=\"wce-product-header\"\u003e\n\u003cp class=\"wce-eyebrow\"\u003eWhisperKOOL Blow-Through Series\u003c\/p\u003e\n\u003ch2\u003eWhisperKOOL Blow-Through 8000 H.E. 220V Split Wine Cellar Cooling System\u003c\/h2\u003e\n\u003cp class=\"wce-product-intro\"\u003eThe WhisperKOOL Blow-Through 8000 H.E. is a configurable split wine cellar cooling system designed for installations where cooling equipment must integrate discreetly into the surrounding architecture. Its evaporator can be concealed in a soffit, above cabinetry, within a wine wall, inside the cellar, or in an adjacent mechanical space while conditioned air is directed through a ducted, ductless, or hybrid airflow arrangement.\u003c\/p\u003e\n\u003cp\u003eThis configuration pairs the Blow-Through 8000 evaporator with a WhisperKOOL 220V High Efficiency condensing unit using a communication cable. The system is intended for custom residential wine rooms, glass wine cellars, commercial wine displays, built-in wine storage, and other projects requiring flexible equipment placement and directional airflow.\u003c\/p\u003e\n\u003cdiv class=\"wce-stats\"\u003e\n\u003cdiv class=\"wce-stat\"\u003e\n\u003cdiv class=\"wce-stat-num\"\u003e4,463–5,544\u003csmall\u003e BTU\/h\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat-lab\"\u003ePublished cooling capacity\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat\"\u003e\n\u003cdiv class=\"wce-stat-num\"\u003e46\u003csmall\u003e dBA\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat-lab\"\u003eEvaporator sound on low\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat\"\u003e\n\u003cdiv class=\"wce-stat-num\"\u003e100\u003csmall\u003e ft.\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat-lab\"\u003eMaximum line-set distance\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat\"\u003e\n\u003cdiv class=\"wce-stat-num\"\u003e3\u003csmall\u003e options\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat-lab\"\u003eDucted, ductless, or hybrid\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-important-notice\"\u003e\n\u003cstrong\u003eRequired selection:\u003c\/strong\u003e One compatible Ducted, Ductless, or Hybrid Airflow Kit must be selected according to the planned supply and return-air arrangement.\u003c\/div\u003e\n\u003c\/header\u003e\u003chr\u003e\n\u003csection class=\"wce-ai-summary\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eProduct Overview\u003c\/span\u003e\n\u003ch2 id=\"expert-summary\"\u003eQuick Expert Summary\u003c\/h2\u003e\n\u003cdiv class=\"wce-summary-grid\"\u003e\n\u003cdiv class=\"wce-summary-item\"\u003e\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cp\u003eCustom wine cellars, wine walls, glass enclosures, soffit installations, built-in cabinetry, commercial wine displays, and projects requiring concealed cooling equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-summary-item\"\u003e\n\u003ch3\u003eAirflow Options\u003c\/h3\u003e\n\u003cp\u003eSupports ducted, ductless, and hybrid configurations. One compatible airflow kit is required to complete the evaporator configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-summary-item\"\u003e\n\u003ch3\u003eSystem Type\u003c\/h3\u003e\n\u003cp\u003eSplit wine cellar cooling system with a remotely located 220V High Efficiency condensing unit and a communication-cable control connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-summary-item\"\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eMust be installed and commissioned by a qualified, licensed HVAC\/R technician. Improper installation can prevent proper operation and void the manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-features\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eKey Features\u003c\/span\u003e\n\u003ch2 id=\"why-choose\"\u003eWhy Choose the Blow-Through 8000 H.E.?\u003c\/h2\u003e\n\u003cp\u003eThe Blow-Through Series is designed for wine cellar projects where a conventional wall-mounted evaporator would interfere with the appearance, layout, or usable wall space of the cellar. Its adaptable airflow system allows the cooling equipment to be integrated around architectural constraints instead of forcing the cellar design around a fixed discharge direction.\u003c\/p\u003e\n\u003cdiv class=\"wce-feature-grid\"\u003e\n\u003cdiv class=\"wce-feature-card\"\u003e\n\u003ch3\u003eConcealed Cooling Integration\u003c\/h3\u003e\n\u003cp\u003eThe evaporator can be positioned in cellars, soffits, attics, cabinetry, or adjacent mechanical spaces, allowing the main cooling equipment to remain less visible within the finished wine cellar.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-feature-card\"\u003e\n\u003ch3\u003eConfigurable Airflow Direction\u003c\/h3\u003e\n\u003cp\u003eSupply and return airflow can be connected to ducts, redirected with airflow deflectors, or configured with one duct and one deflector. This provides flexibility for projects with limited ducting routes or difficult equipment placement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-feature-card\"\u003e\n\u003ch3\u003eQuiet Centrifugal Blower\u003c\/h3\u003e\n\u003cp\u003eThe multi-speed centrifugal blower supports controlled air movement through the selected airflow configuration. Published evaporator sound levels are as low as 46 dBA on low speed when measured at 6 feet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-feature-card\"\u003e\n\u003ch3\u003eBuilt-In Condensate Pump\u003c\/h3\u003e\n\u003cp\u003eThe evaporator includes a condensate pump to help manage moisture removed from the cellar air. The drain system must still be correctly routed, tested, and maintained by the installer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-feature-card\"\u003e\n\u003ch3\u003eLiquid-Temperature Bottle Probe\u003c\/h3\u003e\n\u003cp\u003eThe standard controller uses a bottle probe to monitor liquid temperature rather than responding only to short-term changes in cellar air temperature. This supports more stable control for wine storage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-feature-card\"\u003e\n\u003ch3\u003eService-Friendly Construction\u003c\/h3\u003e\n\u003cp\u003eDual-side service access, a removable coil design, and accessible electrical connections are intended to simplify inspection, maintenance, and component service.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-best-for\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eApplications\u003c\/span\u003e\n\u003ch2 id=\"recommended-applications\"\u003eRecommended Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCustom residential wine cellars\u003c\/li\u003e\n\u003cli\u003eGlass-enclosed wine rooms\u003c\/li\u003e\n\u003cli\u003eFloor-to-ceiling wine walls\u003c\/li\u003e\n\u003cli\u003eWine cooling systems concealed above cabinetry\u003c\/li\u003e\n\u003cli\u003eSoffit-mounted cooling installations\u003c\/li\u003e\n\u003cli\u003eWalk-in wine cellars\u003c\/li\u003e\n\u003cli\u003eRestaurant wine displays\u003c\/li\u003e\n\u003cli\u003eHospitality and commercial wine storage projects\u003c\/li\u003e\n\u003cli\u003eProjects with limited conventional ducting routes\u003c\/li\u003e\n\u003cli\u003eInstallations requiring directional supply and return airflow\u003c\/li\u003e\n\u003cli\u003eWine cellar designs where visible cooling equipment is undesirable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-best-for\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eBuyer Fit\u003c\/span\u003e\n\u003ch2 id=\"buyer-fit\"\u003eIs This the Right System for Your Project?\u003c\/h2\u003e\n\u003cdiv class=\"wce-buyer-grid\"\u003e\n\u003cdiv class=\"wce-buyer-card wce-positive\"\u003e\n\u003ch3\u003eThis system may be a good fit when:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYou need to conceal the evaporator in a soffit, cabinet, attic, cellar, or mechanical space.\u003c\/li\u003e\n\u003cli\u003eYour project requires ducted, ductless, or partially ducted airflow.\u003c\/li\u003e\n\u003cli\u003eThe wine cellar design cannot accommodate a conventional through-the-wall cooling unit.\u003c\/li\u003e\n\u003cli\u003eYou want the heat-generating condensing unit positioned away from the wine cellar.\u003c\/li\u003e\n\u003cli\u003eYour project includes a qualified HVAC\/R professional who can install and commission a split system.\u003c\/li\u003e\n\u003cli\u003eA professional heat-load calculation confirms that the system is appropriately sized.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-buyer-card wce-negative\"\u003e\n\u003ch3\u003eThis system may not be the right choice when:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYou need a plug-in, self-contained through-the-wall cooling unit.\u003c\/li\u003e\n\u003cli\u003eYou cannot accommodate refrigerant lines between the evaporator and condenser.\u003c\/li\u003e\n\u003cli\u003eYou do not have access to a qualified, licensed HVAC\/R installer.\u003c\/li\u003e\n\u003cli\u003eYou need a complete system that requires no field charging or commissioning.\u003c\/li\u003e\n\u003cli\u003eYour project cannot provide the required electrical circuits, service clearances, drainage, or airflow openings.\u003c\/li\u003e\n\u003cli\u003eYou have not confirmed the cellar heat load, insulation, vapor barrier, glass exposure, and surrounding ambient conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-cooling-capacity\"\u003e\u003cspan class=\"wce-eyebrow\"\u003ePerformance\u003c\/span\u003e\n\u003ch2 id=\"cooling-capacity\"\u003eCooling Capacity and System Sizing\u003c\/h2\u003e\n\u003cp\u003eThe Blow-Through 8000 H.E. has a published cooling-capacity range of approximately \u003cstrong\u003e4,463 to 5,544 BTU per hour\u003c\/strong\u003e, depending on operating conditions and system configuration. Actual sensible and total capacity can vary with condenser inlet temperature, evaporator fan speed, airflow arrangement, refrigerant charge, duct resistance, cellar temperature, and installation conditions.\u003c\/p\u003e\n\u003cp\u003eCooling capacity should not be selected from cellar volume alone. A professional heat-load calculation should account for the complete construction and operating environment, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCellar dimensions and ceiling height\u003c\/li\u003e\n\u003cli\u003eInsulation type and R-value\u003c\/li\u003e\n\u003cli\u003eContinuity and condition of the vapor barrier\u003c\/li\u003e\n\u003cli\u003eQuantity and type of glass\u003c\/li\u003e\n\u003cli\u003eExterior walls and solar exposure\u003c\/li\u003e\n\u003cli\u003eConcrete, stone, brick, or other high-mass surfaces\u003c\/li\u003e\n\u003cli\u003eAdjacent-room temperatures\u003c\/li\u003e\n\u003cli\u003eLighting and electrical loads\u003c\/li\u003e\n\u003cli\u003eDoor construction and frequency of opening\u003c\/li\u003e\n\u003cli\u003eSupply and return duct lengths and restrictions\u003c\/li\u003e\n\u003cli\u003eCondenser ambient temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"wce-warning-notice\"\u003e\n\u003cstrong\u003eSizing notice:\u003c\/strong\u003e Manufacturer capacities are based on a fully insulated and sealed wine cellar with a proper vapor barrier. An undersized system may operate continuously, fail to maintain the desired cellar temperature, or experience premature component wear. Always complete a project-specific heat-load calculation before selecting a cooling system.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-airflow-configurations\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eConfiguration\u003c\/span\u003e\n\u003ch2 id=\"airflow-guide\"\u003eRequired Airflow Configuration\u003c\/h2\u003e\n\u003cp\u003eThe Blow-Through 8000 evaporator requires one airflow configuration kit. The correct kit depends on whether the supply air, return air, or both air paths will be connected to ducts.\u003c\/p\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eConfiguration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eKit Components\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eAirflow Arrangement\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCommon Applications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDucted Airflow Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo duct plenums\u003c\/td\u003e\n\u003ctd\u003eBoth supply and return air are fully ducted.\u003c\/td\u003e\n\u003ctd\u003eRemote evaporator placement, concealed registers, mechanical rooms, attics, and installations where both air paths must be routed away from the unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuctless Airflow Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo airflow deflectors\u003c\/td\u003e\n\u003ctd\u003eSupply and return air are directed from the evaporator without conventional duct runs.\u003c\/td\u003e\n\u003ctd\u003eSoffits, cabinetry, wine walls, and installations where the evaporator is positioned close to the conditioned cellar space.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHybrid Airflow Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne duct plenum and one airflow deflector\u003c\/td\u003e\n\u003ctd\u003eOne air path is ducted while the other is directed with a deflector.\u003c\/td\u003e\n\u003ctd\u003eProjects where only the supply or return requires ducting because of architectural or equipment-placement restrictions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eDeflectors permit the supply and return air to be directed toward the front, rear, or downward, depending on the selected configuration and available installation space. The final orientation should be established during project planning so that conditioned air circulates through the cellar without short cycling directly back into the return.\u003c\/p\u003e\n\u003cdiv class=\"wce-important-notice\"\u003e\n\u003cstrong\u003eRequired selection:\u003c\/strong\u003e The evaporator is not complete without a compatible airflow kit. Select the Ducted, Ductless, or Hybrid Airflow Kit when ordering.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-ducting-guidance\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eDuct Design\u003c\/span\u003e\n\u003ch2 id=\"ducting-requirements\"\u003eDucting and Register Planning\u003c\/h2\u003e\n\u003cp\u003eFor the Blow-Through 8000 evaporator, the published duct guideline is a maximum 25-foot duct run using 10-inch ducting. Duct length, bends, restrictions, transitions, register free area, and poor insulation can reduce airflow and cooling performance.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse correctly sized supply and return ducts.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs as short and direct as the project permits.\u003c\/li\u003e\n\u003cli\u003eMinimize sharp bends, compressed flexible duct, and restrictive transitions.\u003c\/li\u003e\n\u003cli\u003eSeal duct connections to prevent conditioned-air leakage.\u003c\/li\u003e\n\u003cli\u003eInsulate ductwork and maintain vapor-barrier integrity to prevent condensation.\u003c\/li\u003e\n\u003cli\u003eUse registers and louvers that provide sufficient free area for the required airflow.\u003c\/li\u003e\n\u003cli\u003eDo not place the supply and return where air will immediately recirculate between them.\u003c\/li\u003e\n\u003cli\u003eConfirm actual airflow during system commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRegister and louver selection must be based on free area rather than nominal face dimensions alone. Decorative registers that are too restrictive can increase static pressure, reduce airflow, decrease capacity, and contribute to coil icing or poor temperature distribution.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-features\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eCondenser\u003c\/span\u003e\n\u003ch2 id=\"high-efficiency-condenser\"\u003e220V High Efficiency Condenser\u003c\/h2\u003e\n\u003cp\u003eThis configuration uses the WhisperKOOL 220V High Efficiency condenser designed for the Blow-Through 8000 evaporator. The evaporator receives 115V power, while the High Efficiency condenser requires 210–230V power. A 24V, 18\/5 communication cable is used between the system components.\u003c\/p\u003e\n\u003ch3\u003eHigh Efficiency Condenser Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote placement separates condenser heat and compressor operation from the wine cellar.\u003c\/li\u003e\n\u003cli\u003ePublished sound level as low as 48 dBA at 6 feet under the stated test condition.\u003c\/li\u003e\n\u003cli\u003eDesigned to operate across ambient temperatures from approximately -20°F to 120°F.\u003c\/li\u003e\n\u003cli\u003eSupports refrigerant line-set distances up to 100 feet when installed according to manufacturer requirements.\u003c\/li\u003e\n\u003cli\u003eUses a 210–230V electrical supply for the condenser.\u003c\/li\u003e\n\u003cli\u003eProvides a split-system solution for concealed and architecturally integrated wine cellar cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"wce-warning-notice\"\u003e\n\u003cstrong\u003eElectrical clarification:\u003c\/strong\u003e “220V H.E.” refers to the High Efficiency condenser. The published installation requirements specify 115V power for the evaporator and 220V power for the condenser. Electrical work must comply with the manufacturer instructions and applicable local requirements.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-controller-options\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eControl Options\u003c\/span\u003e\n\u003ch2 id=\"temperature-control\"\u003eTemperature Control Options\u003c\/h2\u003e\n\u003ch3\u003eStandard WhisperKOOL Controller and Bottle Probe\u003c\/h3\u003e\n\u003cp\u003eThe standard evaporator configuration includes an advanced digital controller with a 50-foot cable and a liquid-temperature-measuring bottle probe with a 50-foot cable. The bottle probe is intended to monitor liquid temperature and provide more stable control than an air-only sensor exposed to brief temperature fluctuations.\u003c\/p\u003e\n\u003ch3\u003eOptional 24V Thermostat Conversion Kit\u003c\/h3\u003e\n\u003cp\u003eA 24V thermostat conversion kit is available for projects designed around a separately sourced 24V thermostat. Selecting this conversion changes the standard control configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe WhisperKOOL smart thermostat is not included.\u003c\/li\u003e\n\u003cli\u003eThe customer or installer must supply a compatible 24V thermostat.\u003c\/li\u003e\n\u003cli\u003eThe standard WhisperKOOL controller and bottle probe are removed when the conversion kit is selected.\u003c\/li\u003e\n\u003cli\u003eWhisperKOOL does not provide technical support for third-party smart thermostats.\u003c\/li\u003e\n\u003cli\u003eThermostat suitability, programming, wiring, and sensor behavior must be confirmed by the project professional.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"wce-important-notice\"\u003e\n\u003cstrong\u003eControl-selection notice:\u003c\/strong\u003e Do not select the 24V conversion kit unless the project has been specifically designed for a third-party 24V thermostat and the loss of the standard liquid-temperature bottle probe has been considered.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-technical-specifications\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eSpecifications\u003c\/span\u003e\n\u003ch2 id=\"specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct\u003c\/th\u003e\n\u003ctd\u003eWhisperKOOL Blow-Through 8000 H.E. Split Wine Cellar Cooling System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003e220V High Efficiency condenser with communication cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eS-WKBT-8000-220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSystem Type\u003c\/th\u003e\n\u003ctd\u003eSplit wine cellar cooling system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePublished Cooling Capacity\u003c\/th\u003e\n\u003ctd\u003eApproximately 4,463–5,544 BTU\/h, depending on configuration and operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEvaporator Refrigerant Compatibility\u003c\/th\u003e\n\u003ctd\u003eR-134a \/ R-513A as identified on the current manufacturer product sheet; the supplied 4000\/8000 charging documentation specifies R-134a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEvaporator Electrical Supply\u003c\/th\u003e\n\u003ctd\u003e115V; dedicated circuit requirements must be confirmed from the installation documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondenser Electrical Supply\u003c\/th\u003e\n\u003ctd\u003e210–230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommunication Wiring\u003c\/th\u003e\n\u003ctd\u003e24V communication cable, 18\/5 wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEvaporator Running Amperage\u003c\/th\u003e\n\u003ctd\u003eApproximately 1.4 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEvaporator Weight\u003c\/th\u003e\n\u003ctd\u003eApproximately 65 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEvaporator Airflow\u003c\/th\u003e\n\u003ctd\u003eApproximately 262 CFM low, 352 CFM medium, and 430 CFM high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEvaporator Sound Level\u003c\/th\u003e\n\u003ctd\u003eAs low as 46 dBA low, 53 dBA medium, and 59 dBA high when measured at 6 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDucted Evaporator Dimensions\u003c\/th\u003e\n\u003ctd\u003eApproximately 30.5 inches L × 15.5 inches W × 15.5 inches H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuctless Evaporator Dimensions\u003c\/th\u003e\n\u003ctd\u003eApproximately 41.52 inches L × 15.5 inches W × 15.5 inches H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHybrid Evaporator Dimensions\u003c\/th\u003e\n\u003ctd\u003eApproximately 36.01 inches L × 15.5 inches W × 15.5 inches H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePublished Duct Guideline\u003c\/th\u003e\n\u003ctd\u003e10-inch ducting; maximum 25-foot run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondensate Management\u003c\/th\u003e\n\u003ctd\u003eBuilt-in condensate pump with 1\/4-inch drain line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard Temperature Control\u003c\/th\u003e\n\u003ctd\u003eAdvanced digital controller and liquid-temperature bottle probe, each with a 50-foot cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRequired Airflow Kit\u003c\/th\u003e\n\u003ctd\u003eDucted, Ductless, or Hybrid Airflow Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondenser Model Class\u003c\/th\u003e\n\u003ctd\u003eH.E. 8000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondenser Dimensions\u003c\/th\u003e\n\u003ctd\u003eApproximately 31.18 inches L × 10.75 inches W × 21.18 inches H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondenser Weight\u003c\/th\u003e\n\u003ctd\u003eApproximately 56 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondenser Running Amperage\u003c\/th\u003e\n\u003ctd\u003eApproximately 3.66 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondenser Sound Level\u003c\/th\u003e\n\u003ctd\u003eAs low as 48 dBA at 6 feet under the stated manufacturer test condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondenser Ambient Operating Range\u003c\/th\u003e\n\u003ctd\u003eApproximately -20°F to 120°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Refrigerant Line Distance\u003c\/th\u003e\n\u003ctd\u003eUp to 100 feet when installed according to manufacturer requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLiquid Line\u003c\/th\u003e\n\u003ctd\u003e1\/4-inch OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuction Line, 1–50 ft\u003c\/th\u003e\n\u003ctd\u003e1\/2-inch OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuction Line, 51–100 ft Horizontal\u003c\/th\u003e\n\u003ctd\u003e5\/8-inch OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation Requirement\u003c\/th\u003e\n\u003ctd\u003eQualified, licensed HVAC\/R technician required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLine Set Included\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"wce-specification-disclaimer\"\u003eSpecifications are based on the supplied manufacturer documentation and may be revised. Confirm final dimensions, electrical requirements, line-set sizing, refrigerant requirements, clearances, and installation procedures before construction or installation.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-quick-specifications\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eProject Planning\u003c\/span\u003e\n\u003ch2 id=\"required-selections\"\u003eRequired Project Selections\u003c\/h2\u003e\n\u003cp\u003eThe following project decisions must be completed before ordering and installation:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect an airflow kit:\u003c\/strong\u003e Ducted, Ductless, or Hybrid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm system sizing:\u003c\/strong\u003e Complete a professional wine cellar heat-load calculation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan evaporator placement:\u003c\/strong\u003e Confirm service access, airflow direction, drainage, and required clearances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan condenser placement:\u003c\/strong\u003e Confirm ambient conditions, electrical supply, airflow, structural support, and service access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign the refrigerant line set:\u003c\/strong\u003e Determine total length, vertical rise, tubing diameter, insulation, and oil-management requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect the control method:\u003c\/strong\u003e Standard WhisperKOOL controller and bottle probe or optional 24V thermostat conversion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArrange professional installation:\u003c\/strong\u003e Use a qualified, licensed HVAC\/R technician familiar with split-system charging and commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-optional-addons\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eOptional Add-Ons\u003c\/span\u003e\n\u003ch2 id=\"optional-add-ons\"\u003eOptional Add-Ons\u003c\/h2\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eOptional Add-On\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24V Thermostat Conversion Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConverts the system for use with a separately sourced 24V thermostat. Selecting the conversion removes the standard WhisperKOOL controller and bottle probe.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExterior Enclosure for Omega Condenser\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntended for compatible Omega condenser installations where an approved exterior housing is required. Confirm applicability to the condenser selected for the project.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOmega Condenser Ducting Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports compatible indoor Omega condenser installations requiring condenser-air ducting. Confirm compatibility before ordering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-installation-requirements\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eInstallation\u003c\/span\u003e\n\u003ch2 id=\"installation-requirements\"\u003eInstallation Requirements\u003c\/h2\u003e\n\u003cp\u003eThe Blow-Through 8000 H.E. is professional HVAC\/R equipment. It is not a pre-charged, plug-in appliance and must be installed, evacuated, charged, adjusted, tested, and commissioned by a qualified, licensed HVAC\/R technician.\u003c\/p\u003e\n\u003ch3\u003eBefore Installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the selected system matches the completed cellar heat-load calculation.\u003c\/li\u003e\n\u003cli\u003eConfirm the selected airflow kit and final supply-and-return orientation.\u003c\/li\u003e\n\u003cli\u003eProvide the required power supplies for the evaporator and condenser.\u003c\/li\u003e\n\u003cli\u003eProvide 18\/5 communication wiring for the 220V H.E. configuration.\u003c\/li\u003e\n\u003cli\u003ePlan an insulated refrigerant line set; the line set is not included.\u003c\/li\u003e\n\u003cli\u003eProvide sufficient space for equipment airflow and future service.\u003c\/li\u003e\n\u003cli\u003ePlan and test condensate drainage.\u003c\/li\u003e\n\u003cli\u003eConfirm register, louver, and duct free area before finish work is completed.\u003c\/li\u003e\n\u003cli\u003eEnsure the wine cellar is completely insulated and sealed with a proper vapor barrier.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEquipment Clearance\u003c\/h3\u003e\n\u003cp\u003eThe supplied quick-start documentation calls for a minimum clearance of approximately 3 feet around the evaporator and condenser. Project conditions and the complete installation manual should be reviewed before the equipment location is finalized.\u003c\/p\u003e\n\u003ch3\u003eRefrigerant Line Planning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLiquid line: 1\/4-inch OD\u003c\/li\u003e\n\u003cli\u003eSuction line up to 50 feet: 1\/2-inch OD\u003c\/li\u003e\n\u003cli\u003eSuction line from 51 to 100 feet horizontally: 5\/8-inch OD\u003c\/li\u003e\n\u003cli\u003eRecord the total line-set length and vertical rise.\u003c\/li\u003e\n\u003cli\u003eWhen the condenser is positioned above the evaporator, oil-saving bends are required at the manufacturer-specified intervals.\u003c\/li\u003e\n\u003cli\u003eSeal all suction-line insulation without gaps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEvacuation and Leak Testing\u003c\/h3\u003e\n\u003cp\u003eThe installer must follow the complete manufacturer instructions. The quick-start procedure calls for nitrogen flow during brazing, a pressure test at 250 PSI for 15 minutes, leak inspection, and evacuation to 500 microns using a digital micron gauge.\u003c\/p\u003e\n\u003ch3\u003eRefrigerant Charging and TXV Adjustment\u003c\/h3\u003e\n\u003cp\u003eThe supplied 4000\/8000 charge documentation specifies R-134a charging procedures and states that the TXV must be adjusted during commissioning. The initial charge is based on line-set length, but final operation must be verified through pressure, superheat, subcooling, temperature, voltage, and amperage measurements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRun the system under load before taking final readings.\u003c\/li\u003e\n\u003cli\u003eConfirm airflow across the evaporator and condenser.\u003c\/li\u003e\n\u003cli\u003eVerify bottle-probe placement and insulation.\u003c\/li\u003e\n\u003cli\u003eConfirm that refrigerant-line insulation is completely sealed.\u003c\/li\u003e\n\u003cli\u003eCharge the system slowly and monitor compressor amperage.\u003c\/li\u003e\n\u003cli\u003eAdjust the TXV only according to the manufacturer procedure.\u003c\/li\u003e\n\u003cli\u003eAllow the system to stabilize before rechecking measurements.\u003c\/li\u003e\n\u003cli\u003eRecord the final refrigerant charge and commissioning readings on the warranty checklist.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"wce-danger-notice\"\u003e\n\u003cstrong\u003eWarranty requirement:\u003c\/strong\u003e Split systems must be professionally installed. The applicable R-134a Split System Warranty Checklist must be completed, submitted, and approved to activate the manufacturer warranty.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-included\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eIn the Box\u003c\/span\u003e\n\u003ch2 id=\"package-details\"\u003ePackage and Project-Supplied Components\u003c\/h2\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eComponent\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eStatus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlow-Through 8000 evaporator\u003c\/td\u003e\n\u003ctd\u003eSystem component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible 220V High Efficiency condenser\u003c\/td\u003e\n\u003ctd\u003eSystem component for this configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard digital controller\u003c\/td\u003e\n\u003ctd\u003eIncluded unless the 24V thermostat conversion is selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid-temperature bottle probe\u003c\/td\u003e\n\u003ctd\u003eIncluded unless the 24V thermostat conversion is selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in evaporator condensate pump\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDucted, Ductless, or Hybrid Airflow Kit\u003c\/td\u003e\n\u003ctd\u003eRequired selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant line set\u003c\/td\u003e\n\u003ctd\u003eNot included; supplied and sized by the installer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField refrigerant charge\u003c\/td\u003e\n\u003ctd\u003eProvided and adjusted by the installing HVAC\/R technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuctwork, registers, and louvers\u003c\/td\u003e\n\u003ctd\u003eProject supplied unless separately specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical circuits and disconnects\u003c\/td\u003e\n\u003ctd\u003eProject supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThird-party 24V thermostat\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eConfirm the final bill of materials and package contents before ordering. Airflow kits, accessories, installation materials, ductwork, line sets, electrical work, and field labor may be ordered or supplied separately.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-maintenance\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eMaintenance\u003c\/span\u003e\n\u003ch2 id=\"maintenance-requirements\"\u003eMaintenance Requirements\u003c\/h2\u003e\n\u003cp\u003eAnnual professional maintenance is required to support reliable system operation and maintain warranty eligibility. Maintenance frequency may need to increase in dusty environments, commercial applications, or installations with restrictive airflow conditions.\u003c\/p\u003e\n\u003ch3\u003eRecommended Inspection and Maintenance Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInspect duct insulation and vapor-barrier integrity.\u003c\/li\u003e\n\u003cli\u003eClean supply and return grilles or registers.\u003c\/li\u003e\n\u003cli\u003eInspect and clean filters as applicable.\u003c\/li\u003e\n\u003cli\u003eInspect evaporator and condenser coils for dirt, fouling, damage, and evidence of leaks.\u003c\/li\u003e\n\u003cli\u003eClean coils using appropriate service procedures.\u003c\/li\u003e\n\u003cli\u003eInspect the drain pan, drain line, condensate pump, pump reservoir, and water sensor.\u003c\/li\u003e\n\u003cli\u003eClear drain obstructions and perform a condensate drainage test.\u003c\/li\u003e\n\u003cli\u003eInspect electrical connections, contactors, and relays.\u003c\/li\u003e\n\u003cli\u003eConfirm evaporator and condenser fan operation.\u003c\/li\u003e\n\u003cli\u003eMeasure system voltage and amperage.\u003c\/li\u003e\n\u003cli\u003eCheck refrigerant pressures, superheat, and subcooling.\u003c\/li\u003e\n\u003cli\u003eInspect the sight glass and moisture indicator.\u003c\/li\u003e\n\u003cli\u003eVerify controller probes and bottle-probe condition.\u003c\/li\u003e\n\u003cli\u003eClean the bottle probe with a clean towel or rag.\u003c\/li\u003e\n\u003cli\u003eRecord identified issues and complete required repairs or adjustments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRefrigerant adjustments, TXV adjustments, electrical service, coil repair, and condensate-pump repair should be performed only by qualified service personnel.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-warranty\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eWarranty\u003c\/span\u003e\n\u003ch2 id=\"warranty-information\"\u003eWarranty Information\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer documentation identifies a limited two-year split-system warranty with an additional one-year installation grace period. Warranty eligibility depends on correct professional installation, proper commissioning, required maintenance, and manufacturer approval of the applicable warranty checklist.\u003c\/p\u003e\n\u003cp\u003eThe installer must document information such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstaller and company contact information\u003c\/li\u003e\n\u003cli\u003eModel and serial numbers\u003c\/li\u003e\n\u003cli\u003eLine-set length, vertical rise, and tubing diameter\u003c\/li\u003e\n\u003cli\u003ePressure and temperature readings\u003c\/li\u003e\n\u003cli\u003eSuperheat and subcooling measurements\u003c\/li\u003e\n\u003cli\u003eRefrigerant charge weight\u003c\/li\u003e\n\u003cli\u003eVoltage and amperage\u003c\/li\u003e\n\u003cli\u003eCondensate-drain test results\u003c\/li\u003e\n\u003cli\u003eSystem startup date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"wce-warning-notice\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e The warranty is not valid until the required checklist has been submitted to and approved by WhisperKOOL. Review the current manufacturer warranty documentation for complete terms, exclusions, and claim procedures.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-resources\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eResources\u003c\/span\u003e\n\u003ch2 id=\"downloads-resources\"\u003eOfficial Product Resources\u003c\/h2\u003e\n\u003cp\u003eReview the applicable installation, configuration, charging, airflow, and maintenance documentation with the wine cellar designer and licensed HVAC\/R installer before purchasing or installing the system.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Commissioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_4000_8000_Condenser_QuickStartGuide.pdf?v=1785463169\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL 4000 and 8000 Condenser Quick Start Guide\" target=\"_blank\"\u003e WhisperKOOL 4000\/8000 Condenser Quick Start Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Blow_Through_Series_HE_OM.pdf?v=1785318428\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Series High Efficiency Owner and Installation Manual\" target=\"_blank\"\u003e Blow-Through Series High Efficiency Owner and Installation Manual \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_4000_8000_CHARGE_CHART.pdf?v=1785463166\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL 4000 and 8000 Refrigerant Charge Chart\" target=\"_blank\"\u003e WhisperKOOL 4000\/8000 Refrigerant Charge Chart \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications and Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Blow-Through_Product_Sheet.pdf?v=1785318361\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Series Product Sheet\" target=\"_blank\"\u003e WhisperKOOL Blow-Through Series Product Sheet \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Blow_Through_Series_4000_8000_Evaporator.pdf?v=1785463165\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through 4000 and 8000 Evaporator Drawing\" target=\"_blank\"\u003e Blow-Through 4000\/8000 Evaporator Drawing \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Blow-Through_Configuration_Sheet.pdf?v=1785318341\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Configuration Sheet\" target=\"_blank\"\u003e Blow-Through Airflow Configuration Sheet \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Blow_Through_Series_Sales_Sheet_WEB.pdf?v=1785318338\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Series Sales Sheet\" target=\"_blank\"\u003e Blow-Through Series Sales Sheet \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAirflow and Duct Design\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Linear_Register_Ducting_Best_Practices.pdf?v=1785318516\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Linear Register Ducting Best Practices Guide\" target=\"_blank\"\u003e Linear Register Ducting Best Practices \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Register_Louver_Airflow_Requirements.pdf?v=1785318363\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Register and Louver Airflow Requirements\" target=\"_blank\"\u003e Register and Louver Airflow Requirements \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControls and Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/KDT-vs.-24V-Comp-Chart.pdf?v=1785318351\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL KDT versus 24V Thermostat Comparison Chart\" target=\"_blank\"\u003e KDT vs. 24V Thermostat Comparison Chart \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Maintenance_Checklist_Blow_Through_Series.pdf?v=1785318338\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Series Maintenance Checklist\" target=\"_blank\"\u003e Blow-Through Series Maintenance Checklist \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-faq\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eFAQ\u003c\/span\u003e\n\u003ch2 id=\"faq\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat is the WhisperKOOL Blow-Through 8000 H.E.?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eIt is a split wine cellar cooling system designed for concealed and configurable installation. The evaporator can be integrated into a soffit, cabinet, wine wall, cellar, attic, or adjacent mechanical space, while a remote 220V High Efficiency condenser rejects heat away from the cellar.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eIs the entire system powered by 220V?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eNo. In this High Efficiency configuration, the published installation requirements specify 115V power for the evaporator and 210–230V power for the condenser. The installer must also provide the required communication wiring between the components.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat is the cooling capacity of the Blow-Through 8000 H.E.?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe supplied product information identifies a published capacity range of approximately 4,463 to 5,544 BTU per hour. Actual performance varies with condenser temperature, evaporator fan speed, airflow configuration, duct resistance, refrigerant charge, and cellar conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow large of a wine cellar can this system cool?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eA reliable maximum cubic-foot rating cannot be determined without evaluating the cellar construction. Glass, insulation, vapor-barrier quality, ceiling height, surrounding temperatures, exterior exposure, lighting, doors, and duct design all affect the heat load. A professional calculation should be completed before selecting the system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhich airflow kit should I choose?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eChoose the Ducted Airflow Kit when both supply and return will be connected to ducts. Choose the Ductless Airflow Kit when both air paths will be directed with deflectors near the evaporator. Choose the Hybrid Airflow Kit when one air path will be ducted and the other will use a deflector.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eIs an airflow kit required?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eYes. A Ducted, Ductless, or Hybrid Airflow Kit is required to complete the evaporator's supply-and-return airflow configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan the Blow-Through 8000 be installed above a wine wall?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eYes, provided the project includes sufficient structural support, service access, drainage, airflow openings, duct or deflector clearance, and an installation layout approved by the project professionals. Soffits, cabinetry, and wine walls are among the intended applications of the Blow-Through Series.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan it be used for a glass wine cellar?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eIt can be used for properly designed glass wine cellars, but glass creates a greater heat load than insulated opaque walls. The glass type, total glass area, room exposure, door leakage, and surrounding temperature must be included in the heat-load calculation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eDoes the system include the refrigerant line set?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eNo. The refrigerant line set is not included. The licensed HVAC\/R installer must provide correctly sized copper tubing, insulation, fittings, and other field installation materials based on the total run and vertical rise.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow far can the condenser be installed from the evaporator?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe manufacturer product sheet states that the condensing unit can be installed up to 100 feet of line set from the evaporator when all line-sizing, elevation, oil-management, charging, and installation requirements are followed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat refrigerant does the system use?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe current product sheet identifies evaporator compatibility with R-134a and R-513A, while the supplied 4000\/8000 quick-start and charge-chart documentation specifically instructs installers to use R-134a. The installer must follow the identification labels and documentation applicable to the exact equipment supplied.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eDoes the Blow-Through 8000 have a condensate pump?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eYes. The evaporator is equipped with a built-in condensate pump and a 1\/4-inch drain line. The drain must be correctly routed and tested during installation, then inspected and cleaned as part of regular maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan I use a smart thermostat?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eA separately available 24V thermostat conversion kit permits use of a customer-supplied 24V thermostat. However, a thermostat is not included, the standard WhisperKOOL controller and bottle probe are removed with this conversion, and WhisperKOOL does not provide technical support for third-party smart thermostats.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat is the benefit of the standard bottle probe?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe bottle probe measures liquid temperature, which changes more gradually than the surrounding air. This helps the controller respond to wine-storage conditions rather than reacting only to brief air-temperature changes caused by door openings or normal system cycling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow loud is the Blow-Through 8000?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe manufacturer lists evaporator sound levels as low as 46 dBA on low speed, 53 dBA on medium speed, and 59 dBA on high speed at 6 feet. The 220V High Efficiency condenser is listed as low as 48 dBA at 6 feet under the stated test condition. Actual perceived noise depends on placement, fan speed, duct design, registers, vibration isolation, and surrounding construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan the condenser operate outdoors?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe High Efficiency condenser is engineered for a broad ambient operating range, but its final location, weather exposure, electrical protection, drainage, mounting surface, snowfall clearance, and installation requirements must be confirmed from the applicable manufacturer manual and local project requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan I install this system myself?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eNo. Installation requires specialized HVAC\/R procedures, including refrigerant piping, nitrogen-assisted brazing, pressure testing, evacuation, charging, TXV adjustment, electrical work, condensate testing, and system commissioning. A qualified, licensed HVAC\/R technician is required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eDoes the system arrive fully charged with refrigerant?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eNo. The split system requires field evacuation and refrigerant charging after the line set has been installed and leak-tested. The final charge must be adjusted according to the manufacturer charge chart and verified through operating measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eIs TXV adjustment required?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eYes. The supplied charge documentation states that TXV adjustment is required. This procedure must be completed by the installer after the system has been correctly charged and allowed to stabilize under load.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow often does the system require maintenance?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe manufacturer requires annual maintenance to maintain warranty eligibility. Conditions such as dust, commercial use, long operating hours, or restrictive airflow may require more frequent inspection and cleaning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat is required to activate the warranty?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe applicable split-system warranty checklist must be completed with installer information, equipment details, line-set information, refrigerant charge, pressure and temperature measurements, electrical readings, condensate-test results, and startup information. The checklist must then be submitted to and approved by WhisperKOOL.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhy are proper registers and louvers important?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eRegisters and louvers that do not provide enough free area restrict airflow. Excessive restriction can reduce cooling capacity, increase noise, create uneven cellar temperatures, and contribute to operational problems. Register selection should therefore be based on required airflow and free area, not appearance alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat should be completed before ordering?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eComplete the cellar heat-load calculation, choose the airflow configuration, confirm evaporator and condenser locations, plan the line set and drainage, verify electrical requirements, decide between the standard controller and optional 24V conversion, and confirm that a licensed HVAC\/R installer is available.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-final-guidance\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eProfessional Planning\u003c\/span\u003e\n\u003ch2 id=\"professional-planning\"\u003eProfessional Wine Cellar Planning Recommended\u003c\/h2\u003e\n\u003cp\u003eThe performance of a split wine cellar cooling system depends on more than the equipment model. Cellar construction, vapor sealing, glass exposure, duct design, register placement, equipment location, line-set design, refrigerant commissioning, and ongoing maintenance all affect the result.\u003c\/p\u003e\n\u003cp\u003eHave the cellar and cooling layout reviewed before ordering. Product planning should confirm the equipment configuration and installation requirements, while all HVAC\/R, electrical, drainage, structural, and code-related work should be completed by appropriately qualified project professionals.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/section\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52143299952860,"sku":"S-WKBT-8000-220","price":7905.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/whisperkool-blow-through-8000-he-220v-split-wine-cellar-cooling-system-main_webp.webp?v=1785468732","url":"https:\/\/winecoolersempire.com\/products\/whisperkool-blow-through-8000-he-220v-split-wine-cellar-cooling-system","provider":"Wine Coolers Empire","version":"1.0","type":"link"}