{"product_id":"whisperkool-mini-blow-through-220v-he-wine-cellar-cooling-system","title":"WhisperKOOL Mini Blow-Through 220V H.E. Wine Cellar Cooling System – S-WKBT-MINI-220","description":"\u003csection class=\"wce-product-page\"\u003e\u003cheader class=\"wce-product-header\"\u003e\n\u003cp class=\"wce-eyebrow\"\u003eWhisperKOOL Blow-Through Series\u003c\/p\u003e\n\u003ch2\u003eWhisperKOOL Mini Blow-Through 220V H.E. Wine Cellar Cooling System S-WKBT-MINI-220\u003c\/h2\u003e\n\u003cp class=\"wce-product-intro\"\u003eThe \u003cstrong\u003eWhisperKOOL Mini Blow-Through 220V H.E. Wine Cellar Cooling System\u003c\/strong\u003e is a compact split-system solution designed for concealed wine cellar installations where traditional cooling equipment would interfere with the finished design. The system supports \u003cstrong\u003educted, ductless, and hybrid airflow configurations\u003c\/strong\u003e, allowing the evaporator to be integrated into soffits, custom cabinetry, wine walls, attics, or adjacent mechanical spaces.\u003c\/p\u003e\n\u003cp\u003ePaired with a \u003cstrong\u003e220V High Efficiency condensing unit\u003c\/strong\u003e, the Mini Blow-Through provides flexible equipment placement, configurable air delivery, liquid-temperature monitoring, integrated condensate management, and professional service access. It is intended for properly insulated and sealed wine cellars and must be installed and commissioned by a qualified HVAC-R technician.\u003c\/p\u003e\n\u003cdiv class=\"wce-stats\"\u003e\n\u003cdiv class=\"wce-stat\"\u003e\n\u003cdiv class=\"wce-stat-num\"\u003e500\u003csmall\u003e cu. ft.\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat-lab\"\u003eSuggested cellar size\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat\"\u003e\n\u003cdiv class=\"wce-stat-num\"\u003e2,722\u003csmall\u003e BTU\/h\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat-lab\"\u003eTotal at 75°F, high fan\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat\"\u003e\n\u003cdiv class=\"wce-stat-num\"\u003e48\u003csmall\u003e dBA\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat-lab\"\u003ePublished condenser sound\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat\"\u003e\n\u003cdiv class=\"wce-stat-num\"\u003e100\u003csmall\u003e ft.\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat-lab\"\u003eMaximum line-set distance\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-important-notice\"\u003e\n\u003cstrong\u003eRequired selection:\u003c\/strong\u003e One airflow configuration kit must be selected with the system. Choose the Ducted Airflow Kit, Ductless Airflow Kit, or Hybrid Airflow Kit according to the planned supply and return-air arrangement.\u003c\/div\u003e\n\u003c\/header\u003e\u003chr\u003e\n\u003csection class=\"wce-ai-summary\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eProduct Overview\u003c\/span\u003e\n\u003ch2\u003eProduct Summary\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eWhisperKOOL Mini Blow-Through S-WKBT-MINI-220\u003c\/strong\u003e is a concealed 220V split-system wine cellar cooling solution for approximately \u003cstrong\u003e500 cubic feet\u003c\/strong\u003e under qualifying cellar conditions. Its compact evaporator can deliver air through two ducts, two directional deflectors, or a combined duct-and-deflector arrangement. The standard KDT control configuration uses a liquid-temperature bottle probe, while an optional 24V conversion permits operation through a customer-supplied third-party thermostat.\u003c\/p\u003e\n\u003cp\u003eThis system is best suited to projects that require professional refrigeration installation, remote condenser placement, adaptable airflow, and a less visible cooling solution than a conventional through-the-wall unit.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-quick-specifications\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eAt a Glance\u003c\/span\u003e\n\u003ch2\u003eQuick Product Specifications\u003c\/h2\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct\u003c\/th\u003e\n\u003ctd\u003eWhisperKOOL Mini Blow-Through 220V H.E. Wine Cellar Cooling System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel \/ SKU\u003c\/th\u003e\n\u003ctd\u003eS-WKBT-MINI-220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSystem Type\u003c\/th\u003e\n\u003ctd\u003eAir-cooled split-system wine cellar cooling system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuggested Cellar Size\u003c\/th\u003e\n\u003ctd\u003eApproximately 500 cu. ft. when the cellar is properly insulated, sealed, and protected by a complete vapor barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAirflow Configurations\u003c\/th\u003e\n\u003ctd\u003eDucted, ductless, or hybrid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRequired Airflow Kit\u003c\/th\u003e\n\u003ctd\u003eOne Ducted, Ductless, or Hybrid Airflow Kit must be selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEvaporator Voltage\u003c\/th\u003e\n\u003ctd\u003e220V configuration for this model; dedicated 15-amp circuit required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondenser Voltage\u003c\/th\u003e\n\u003ctd\u003e210V–230V, dedicated 15-amp circuit required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRefrigerant\u003c\/th\u003e\n\u003ctd\u003eR-134a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard Control\u003c\/th\u003e\n\u003ctd\u003eKDT digital display with liquid-temperature bottle probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOptional Control\u003c\/th\u003e\n\u003ctd\u003e24V Thermostat Conversion Kit for a customer-supplied third-party thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondensate Management\u003c\/th\u003e\n\u003ctd\u003eIntegrated condensate pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Line-Set Distance\u003c\/th\u003e\n\u003ctd\u003eUp to 100 line feet between evaporator and condenser, subject to proper line sizing and installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLine Set Included\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eQualified, licensed HVAC-R technician required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eLimited 2-year product warranty with up to one additional year of installation grace, subject to WhisperKOOL requirements and approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-best-for\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eBuyer Fit\u003c\/span\u003e\n\u003ch2\u003eWho Is the Mini Blow-Through Best For?\u003c\/h2\u003e\n\u003cp\u003eThe Mini Blow-Through is designed for wine cellar projects where cooling performance must be balanced with architectural integration. It is especially useful when the evaporator needs to be hidden or when the supply and return air cannot follow a conventional through-the-wall layout.\u003c\/p\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003cth\u003eWhy It Fits\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass wine cellars\u003c\/td\u003e\n\u003ctd\u003eAllows mechanical equipment to be concealed while conditioned air is directed into the enclosure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWine walls\u003c\/td\u003e\n\u003ctd\u003eThe compact evaporator can be incorporated into nearby cabinetry, soffits, or service cavities.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom cabinetry\u003c\/td\u003e\n\u003ctd\u003eDirectional deflectors and duct plenums provide greater control over return and supply-air routing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLuxury residential cellars\u003c\/td\u003e\n\u003ctd\u003eSupports a cleaner visual presentation by reducing the amount of exposed mechanical equipment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRestaurants and hospitality projects\u003c\/td\u003e\n\u003ctd\u003eProvides split-system flexibility for custom displays and professionally designed wine-storage areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoffit installations\u003c\/td\u003e\n\u003ctd\u003eThe evaporator is designed for concealed placement when structural support, insulation, access, and airflow requirements are met.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjacent mechanical spaces\u003c\/td\u003e\n\u003ctd\u003eDucted or hybrid airflow can connect a remote evaporator location to the cellar.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-not-recommended\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eBefore You Buy\u003c\/span\u003e\n\u003ch2\u003eWhen This System May Not Be the Right Choice\u003c\/h2\u003e\n\u003cp\u003eThe Mini Blow-Through may not be appropriate when professional HVAC-R installation is unavailable, when the cellar lacks proper insulation or a vapor barrier, or when adequate space cannot be provided for airflow, service access, drain routing, refrigerant piping, and condenser heat rejection.\u003c\/p\u003e\n\u003cp\u003eIt is also not a complete do-it-yourself cooling package. The system requires field-installed refrigerant piping, evacuation, charging, electrical work, commissioning, and submission of the required warranty documentation.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-features\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eKey Features\u003c\/span\u003e\n\u003ch2\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003ch3\u003eConcealed Cooling for Modern Wine Cellars\u003c\/h3\u003e\n\u003cp\u003eThe Mini Blow-Through is designed for installations where the cooling system should remain visually discreet. Depending on the selected airflow kit, the evaporator can be installed within a soffit, cabinet assembly, attic, cellar, or adjacent mechanical area while air is delivered through ducts, registers, or directional deflectors.\u003c\/p\u003e\n\u003ch3\u003eDucted, Ductless, or Hybrid Airflow\u003c\/h3\u003e\n\u003cp\u003eUnlike systems limited to one discharge arrangement, the Blow-Through evaporator can be configured around the physical requirements of the project. Both the return and supply can be ducted, both can use directional deflectors, or one side can be ducted while the other uses a deflector.\u003c\/p\u003e\n\u003ch3\u003eDirectional Airflow Control\u003c\/h3\u003e\n\u003cp\u003eThe available deflector configurations allow supply and return air to be directed toward the front, rear, or downward. This helps installers coordinate airflow with racking, finished millwork, cellar openings, and service access.\u003c\/p\u003e\n\u003ch3\u003eLiquid-Temperature Bottle Probe\u003c\/h3\u003e\n\u003cp\u003eThe standard KDT control system uses a liquid-temperature bottle probe instead of relying only on rapidly changing air temperature. The probe is placed in a bottle filled approximately 75% with water and positioned away from the direct air stream. This provides a temperature reading that more closely represents the stored wine's thermal condition.\u003c\/p\u003e\n\u003ch3\u003eRemote KDT Digital Display\u003c\/h3\u003e\n\u003cp\u003eThe standard controller includes a digital display and a 50-foot display cable. The display can be positioned away from the evaporator for more convenient monitoring and control.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Condensate Pump\u003c\/h3\u003e\n\u003cp\u003eThe evaporator includes an internal condensate pump. This gives the installer greater flexibility when gravity drainage is difficult, although a properly routed and tested drain line is still required.\u003c\/p\u003e\n\u003ch3\u003eTwo-Speed Evaporator Fan\u003c\/h3\u003e\n\u003cp\u003eThe Mini Blow-Through uses a two-speed fan control. Higher fan speed increases airflow and available cooling performance, while lower airflow can reduce sound. Fully ducted installations must be configured in accordance with the official airflow and ducting requirements.\u003c\/p\u003e\n\u003ch3\u003eDual-Side Service Access\u003c\/h3\u003e\n\u003cp\u003eService access is available from both sides of the evaporator, and the removable-coil design helps qualified technicians reach key components for installation and maintenance.\u003c\/p\u003e\n\u003ch3\u003eUpward-Facing Flare Connections\u003c\/h3\u003e\n\u003cp\u003eFlare connections and multiple line-routing knockouts provide installers with several options for routing refrigeration piping into the evaporator. All unused openings and line penetrations must be properly sealed and insulated.\u003c\/p\u003e\n\u003ch3\u003eHigh-Efficiency 220V Condenser\u003c\/h3\u003e\n\u003cp\u003eThe 220V H.E. condenser is designed for efficient remote heat rejection and operation across a broad ambient-temperature range. It can be positioned up to 100 line feet from the evaporator when the correct line sizes, refrigerant charge, oil-management practices, and installation procedures are followed.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-airflow-configurations\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eConfiguration\u003c\/span\u003e\n\u003ch2\u003eChoose the Required Airflow Configuration\u003c\/h2\u003e\n\u003cp\u003eEvery Mini Blow-Through system requires one airflow kit. The correct kit should be chosen during project planning because the supply and return openings, soffit framing, duct routing, and register locations must be coordinated before the evaporator is installed.\u003c\/p\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eIncluded Airflow Components\u003c\/th\u003e\n\u003cth\u003eBest Used When\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDucted Airflow Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 duct plenums\u003c\/td\u003e\n\u003ctd\u003eBoth return and supply air need to travel through insulated ducts to remote cellar registers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuctless Airflow Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 airflow deflectors\u003c\/td\u003e\n\u003ctd\u003eThe evaporator is positioned near the cellar openings and air can be directed through nearby grilles or architectural openings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHybrid Airflow Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 duct plenum and 1 airflow deflector\u003c\/td\u003e\n\u003ctd\u003eOne side of the system needs ducting while the other can draw or discharge air directly through a deflector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDucted Configuration\u003c\/h3\u003e\n\u003cp\u003eIn the fully ducted arrangement, both the return and supply are connected to duct plenums. This configuration is appropriate when the evaporator is located farther from the visible cellar openings or when the project requires concealed supply and return registers.\u003c\/p\u003e\n\u003ch3\u003eDuctless Configuration\u003c\/h3\u003e\n\u003cp\u003eThe ductless arrangement uses two directional deflectors. The return and supply may be directed toward the front, rear, or downward in several supported combinations. “Ductless” refers to the evaporator airflow connection and does not eliminate the need for correctly sized cellar openings or registers.\u003c\/p\u003e\n\u003ch3\u003eHybrid Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hybrid arrangement combines one duct plenum with one directional deflector. This is useful when project conditions allow one air path to connect directly to the cellar while the other must be routed through a duct.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-airflow-warning\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eAirflow Planning\u003c\/span\u003e\n\u003ch2\u003eRegister, Louver, and Airflow Requirements\u003c\/h2\u003e\n\u003cp\u003eDecorative registers and louvers must provide sufficient open area. Restrictive grilles can reduce cooling performance, increase airflow noise, raise static pressure, contribute to evaporator-coil freezing, and shorten equipment life.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCustomer-supplied registers and louvers should provide approximately 50%–65% free area across the register face.\u003c\/li\u003e\n\u003cli\u003eDo not add restrictive mesh, foam, screens, or solid backing behind the register.\u003c\/li\u003e\n\u003cli\u003eFinishes, sealants, and stains must not reduce the final slot opening below the required free area.\u003c\/li\u003e\n\u003cli\u003eRegisters should maintain consistent airflow openings across their usable face.\u003c\/li\u003e\n\u003cli\u003eSupply and return openings must not be blocked by bottles, racking, framing, trim, insulation, or stored cases.\u003c\/li\u003e\n\u003cli\u003eRegister compliance should be verified before fabrication and installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInadequate airflow through customer-supplied registers may affect system performance and warranty coverage.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-ducting-guidance\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eDuct Design\u003c\/span\u003e\n\u003ch2\u003eDucting Guidelines\u003c\/h2\u003e\n\u003cp\u003eFully ducted Mini Blow-Through installations use insulated supply and return ductwork. Duct design has a direct effect on airflow, cooling capacity, sound, and condensate control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse an 8-inch supply duct and an 8-inch return duct for the Mini Blow-Through.\u003c\/li\u003e\n\u003cli\u003eUse insulated ductwork with an exterior vapor barrier.\u003c\/li\u003e\n\u003cli\u003eSupport flexible ductwork to prevent sagging and compression.\u003c\/li\u003e\n\u003cli\u003eKeep duct paths as short and straight as practical.\u003c\/li\u003e\n\u003cli\u003eDo not reduce or squeeze the internal duct diameter.\u003c\/li\u003e\n\u003cli\u003eUse sweeping turns instead of sharp bends whenever possible.\u003c\/li\u003e\n\u003cli\u003eEach 90-degree bend can reduce airflow by approximately 13 CFM.\u003c\/li\u003e\n\u003cli\u003eDo not use more than two 90-degree bends on each duct run.\u003c\/li\u003e\n\u003cli\u003eSeal metal seams, plenum joints, and duct connections with approved HVAC materials.\u003c\/li\u003e\n\u003cli\u003eInstall a 12-inch by 12-inch return-air filter grille where required by the installation instructions.\u003c\/li\u003e\n\u003cli\u003eSet the evaporator fan to high for fully ducted operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe official owner's manual states that ductwork should not exceed 25 feet for an individual run, with a combined maximum of 50 feet for the supply and return runs. Project-specific restrictions, fittings, bends, and register designs can reduce available airflow before those maximum lengths are reached.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-cooling-capacity\"\u003e\u003cspan class=\"wce-eyebrow\"\u003ePerformance\u003c\/span\u003e\n\u003ch2\u003eCooling Capacity\u003c\/h2\u003e\n\u003cp\u003eCooling performance changes with the selected airflow configuration, fan speed, and temperature of the air entering the condenser. The following values are the published sensible and total BTU\/h ratings for the Mini Blow-Through paired with the 220V H.E. condenser.\u003c\/p\u003e\n\u003ch3\u003eFully Ducted Capacity\u003c\/h3\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCondenser Inlet Temperature\u003c\/th\u003e\n\u003cth\u003eMedium Fan\u003c\/th\u003e\n\u003cth\u003eHigh Fan\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e85°F\u003c\/td\u003e\n\u003ctd\u003e1,876 sensible \/ 2,263 total BTU\/h\u003c\/td\u003e\n\u003ctd\u003e1,969 sensible \/ 2,376 total BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75°F\u003c\/td\u003e\n\u003ctd\u003e1,919 sensible \/ 2,333 total BTU\/h\u003c\/td\u003e\n\u003ctd\u003e2,015 sensible \/ 2,450 total BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°F–65°F published condition\u003c\/td\u003e\n\u003ctd\u003e2,198 sensible \/ 2,818 total BTU\/h\u003c\/td\u003e\n\u003ctd\u003e2,308 sensible \/ 2,959 total BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDeflector \/ Ductless Capacity\u003c\/h3\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCondenser Inlet Temperature\u003c\/th\u003e\n\u003cth\u003eMedium Fan\u003c\/th\u003e\n\u003cth\u003eHigh Fan\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e85°F\u003c\/td\u003e\n\u003ctd\u003e2,084 sensible \/ 2,514 total BTU\/h\u003c\/td\u003e\n\u003ctd\u003e2,188 sensible \/ 2,640 total BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75°F\u003c\/td\u003e\n\u003ctd\u003e2,132 sensible \/ 2,592 total BTU\/h\u003c\/td\u003e\n\u003ctd\u003e2,239 sensible \/ 2,722 total BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°F–65°F published condition\u003c\/td\u003e\n\u003ctd\u003e2,442 sensible \/ 3,131 total BTU\/h\u003c\/td\u003e\n\u003ctd\u003e2,564 sensible \/ 3,288 total BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-important-notice\"\u003e\n\u003cstrong\u003eCapacity notice:\u003c\/strong\u003e Published BTU ratings are laboratory or theoretical performance figures and should not be treated as a substitute for a project-specific heat-load calculation.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-sizing\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eSizing\u003c\/span\u003e\n\u003ch2\u003eWine Cellar Sizing Considerations\u003c\/h2\u003e\n\u003cp\u003eThe approximate 500-cubic-foot rating assumes that the cellar is fully insulated, completely sealed, and protected by a correctly installed vapor barrier. Actual cooling demand can increase substantially when the enclosure includes glass, stone, concrete, exterior exposure, high ceilings, lighting, frequent door openings, or inadequate insulation.\u003c\/p\u003e\n\u003cp\u003eUndersizing can prevent the cellar from reaching the target temperature and can cause excessive run time or premature equipment failure. A qualified wine-cellar designer or HVAC-R professional should calculate the heat load before the system is selected.\u003c\/p\u003e\n\u003ch3\u003eFactors That Can Increase Cooling Load\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge glass walls or glass doors\u003c\/li\u003e\n\u003cli\u003eStone, masonry, concrete, or other low-insulation materials\u003c\/li\u003e\n\u003cli\u003eExterior walls, ceilings, floors, or sun exposure\u003c\/li\u003e\n\u003cli\u003eHigh ambient temperatures around the condenser\u003c\/li\u003e\n\u003cli\u003eHigh humidity and air leakage\u003c\/li\u003e\n\u003cli\u003eIncomplete or damaged vapor barriers\u003c\/li\u003e\n\u003cli\u003ePoorly sealed cellar doors\u003c\/li\u003e\n\u003cli\u003eHeat-producing lighting or equipment\u003c\/li\u003e\n\u003cli\u003eRestricted return or supply airflow\u003c\/li\u003e\n\u003cli\u003eLong or restrictive duct installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-technical-specifications\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eSpecifications\u003c\/span\u003e\n\u003ch2\u003eFull Technical Specifications\u003c\/h2\u003e\n\u003ch3\u003eMini Blow-Through Evaporator\u003c\/h3\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEvaporator Model\u003c\/th\u003e\n\u003ctd\u003eMini Blow-Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuggested Cellar Size\u003c\/th\u003e\n\u003ctd\u003eApproximately 500 cu. ft. under qualifying cellar conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e220V configuration for S-WKBT-MINI-220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical Circuit\u003c\/th\u003e\n\u003ctd\u003eDedicated 15-amp circuit required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEvaporator Running Amps\u003c\/th\u003e\n\u003ctd\u003eApproximately 1 amp in the current owner's manual specification table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRefrigerant\u003c\/th\u003e\n\u003ctd\u003eR-134a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEvaporator Cabinet Dimensions\u003c\/th\u003e\n\u003ctd\u003eApproximately 25.05 in. L × 11.34 in. W × 11.17 in. H before airflow accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApproximate Evaporator Weight\u003c\/th\u003e\n\u003ctd\u003e35 lbs. according to the current owner's manual Mini specification table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFan Speeds\u003c\/th\u003e\n\u003ctd\u003eTwo selectable speeds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrain Connection\u003c\/th\u003e\n\u003ctd\u003e1\/2-inch NPT PVC fitting in the current owner's manual; internal condensate pump included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard Thermostat\u003c\/th\u003e\n\u003ctd\u003eKDT advanced digital display with 50-foot display cable and 50-foot liquid-temperature bottle probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOptional Thermostat Configuration\u003c\/th\u003e\n\u003ctd\u003e24V conversion for a customer-supplied third-party thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEvaporator Placement\u003c\/th\u003e\n\u003ctd\u003eCellar, soffit, attic, cabinetry, or adjacent mechanical area when installed according to the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum Front Service Clearance\u003c\/th\u003e\n\u003ctd\u003e12 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e220V H.E. Mini Condenser\u003c\/h3\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondenser Type\u003c\/th\u003e\n\u003ctd\u003eAir-cooled High Efficiency condenser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e210V–230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical Circuit\u003c\/th\u003e\n\u003ctd\u003eDedicated 15-amp circuit required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompressor\u003c\/th\u003e\n\u003ctd\u003eApproximately 0.35 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRunning Amps\u003c\/th\u003e\n\u003ctd\u003eApproximately 1.7 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLRA \/ RLA \/ FLA\u003c\/th\u003e\n\u003ctd\u003e5.3A LRA \/ 1.55A RLA \/ 1.7A FLA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eApproximately 31.18 in. L × 10.75 in. W × 21.18 in. H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApproximately 50.7 lbs. in the current owner's manual Mini system table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSound Level\u003c\/th\u003e\n\u003ctd\u003ePublished as low as approximately 48 dBA at 6 feet under specified conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Range\u003c\/th\u003e\n\u003ctd\u003eDesigned to operate in ambient temperatures from approximately -20°F to 120°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Separation\u003c\/th\u003e\n\u003ctd\u003eUp to 100 line feet from the evaporator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutdoor Installation\u003c\/th\u003e\n\u003ctd\u003eSupported when installed according to the official condenser instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRefrigerant Line Requirements\u003c\/h3\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLine\u003c\/th\u003e\n\u003cth\u003e1–50 Feet\u003c\/th\u003e\n\u003cth\u003eMore Than 50 Feet\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Line\u003c\/td\u003e\n\u003ctd\u003e1\/4-inch OD\u003c\/td\u003e\n\u003ctd\u003e1\/4-inch OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction Line\u003c\/td\u003e\n\u003ctd\u003e3\/8-inch OD\u003c\/td\u003e\n\u003ctd\u003e1\/2-inch OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eOil-saving bends are required at prescribed intervals when the condenser is installed above the evaporator. The installing technician must record line-set length, vertical rise, line diameter, charge weight, pressure readings, temperatures, voltage, and amperage on the warranty checklist.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-controller-options\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eControl Options\u003c\/span\u003e\n\u003ch2\u003eKDT Controller vs. Optional 24V Thermostat Conversion\u003c\/h2\u003e\n\u003cp\u003eThe standard KDT system and the optional 24V conversion use different temperature-control methods. The selection should be made before ordering because choosing the 24V kit changes the factory control configuration.\u003c\/p\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eStandard KDT Controller\u003c\/th\u003e\n\u003cth\u003e24V Thermostat Conversion\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement\u003c\/td\u003e\n\u003ctd\u003eLiquid temperature through a bottle probe\u003c\/td\u003e\n\u003ctd\u003eAmbient air temperature through the third-party thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory preconfigured\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo; third-party thermostat setup is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhisperKOOL wine-protection programming\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eNot provided through the third-party thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem protection alerts\u003c\/td\u003e\n\u003ctd\u003eSupported through the KDT system\u003c\/td\u003e\n\u003ctd\u003eDependent on the third-party thermostat and not equivalent to the KDT feature set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart-home integration\u003c\/td\u003e\n\u003ctd\u003eNot designed as a Wi-Fi smart thermostat\u003c\/td\u003e\n\u003ctd\u003ePossible when a compatible customer-supplied smart thermostat is used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhone application\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eDependent on the selected thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhisperKOOL support for thermostat\u003c\/td\u003e\n\u003ctd\u003eYes, for the WhisperKOOL control system\u003c\/td\u003e\n\u003ctd\u003eNo technical support for the third-party smart thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBottle probe included and used\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-important-notice\"\u003e\n\u003cstrong\u003e24V conversion notice:\u003c\/strong\u003e By selecting the 24V Thermostat Conversion Kit, the system will not be built with the standard WhisperKOOL control or liquid-temperature bottle probe. The purchaser must source a compatible 24V thermostat separately. WhisperKOOL does not provide technical support for third-party smart thermostats.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-installation-requirements\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eInstallation\u003c\/span\u003e\n\u003ch2\u003eProfessional Installation Requirements\u003c\/h2\u003e\n\u003cp\u003eThe WhisperKOOL Mini Blow-Through is a professional split-system refrigeration product. Installation must be completed by a qualified, licensed HVAC-R technician. Improper installation, incorrect charging, inadequate airflow, poor cellar preparation, or failure to complete the warranty checklist can affect performance and void warranty coverage.\u003c\/p\u003e\n\u003ch3\u003eBefore Installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the exact evaporator and condenser voltage shown on the equipment labels.\u003c\/li\u003e\n\u003cli\u003eProvide the required dedicated electrical circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm the selected ducted, ductless, or hybrid airflow arrangement.\u003c\/li\u003e\n\u003cli\u003ePlan supply and return openings before mounting the evaporator.\u003c\/li\u003e\n\u003cli\u003eRoute the line set, drain line, communication wiring, power wiring, controller cable, and bottle-probe cable before the final installation position becomes inaccessible.\u003c\/li\u003e\n\u003cli\u003eVerify that the structure can support the full operating weight of the equipment.\u003c\/li\u003e\n\u003cli\u003eProvide at least 12 inches of front service clearance at the evaporator.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance and ventilation around the condenser.\u003c\/li\u003e\n\u003cli\u003eInstall all required exterior insulation on the evaporator before it is enclosed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEvaporator Insulation\u003c\/h3\u003e\n\u003cp\u003eThe provided insulation blanket must be installed on the required evaporator surfaces before the unit is mounted. The manual also requires additional fiberglass insulation of R-19 or higher around the evaporator when it is installed in a soffit, attic, or similar warm cavity.\u003c\/p\u003e\n\u003cp\u003eFailure to create an effective insulation and vapor-barrier system can lead to condensation, water damage, corrosion, reduced capacity, and warranty problems.\u003c\/p\u003e\n\u003ch3\u003eCellar Preparation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsulate all walls and ceilings.\u003c\/li\u003e\n\u003cli\u003eInstall a continuous vapor barrier on the warm side of the cellar assembly.\u003c\/li\u003e\n\u003cli\u003eSeal every penetration, overlap, cut, conduit, and opening in the vapor barrier.\u003c\/li\u003e\n\u003cli\u003eUse a well-sealed exterior-grade cellar door with weather stripping and a bottom sweep or threshold.\u003c\/li\u003e\n\u003cli\u003ePrevent warm, humid air from leaking into the cellar.\u003c\/li\u003e\n\u003cli\u003eComplete a heat-load calculation before selecting the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRefrigeration Commissioning\u003c\/h3\u003e\n\u003cp\u003eThe system is shipped for professional field installation and must be pressure tested, evacuated, charged, adjusted, and commissioned. The quick-start and charge documentation call for nitrogen flow, pressure testing, evacuation to the required micron level, R-134a charging, and TXV adjustment.\u003c\/p\u003e\n\u003cp\u003eTechnicians must monitor superheat, subcooling, compressor amperage, refrigerant pressures, voltage, and operating temperatures. Charge amounts shown in the official chart are approximate starting points and must be adjusted according to measured system performance.\u003c\/p\u003e\n\u003ch3\u003eApproximate Initial Refrigerant Charge\u003c\/h3\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLine-Set Length\u003c\/th\u003e\n\u003cth\u003eApproximate Initial Charge\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 ft.\u003c\/td\u003e\n\u003ctd\u003e2.00 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 ft.\u003c\/td\u003e\n\u003ctd\u003e2.15 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 ft.\u003c\/td\u003e\n\u003ctd\u003e2.30 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 ft.\u003c\/td\u003e\n\u003ctd\u003e2.45 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 ft.\u003c\/td\u003e\n\u003ctd\u003e2.60 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 ft.\u003c\/td\u003e\n\u003ctd\u003e2.75 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e70 ft.\u003c\/td\u003e\n\u003ctd\u003e2.90 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80 ft.\u003c\/td\u003e\n\u003ctd\u003e3.05 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e90 ft.\u003c\/td\u003e\n\u003ctd\u003e3.20 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 ft.\u003c\/td\u003e\n\u003ctd\u003e3.35 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThese figures are approximate initial charge amounts, not final commissioning targets. Only a qualified HVAC-R technician should charge or adjust the TXV.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-included\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eIn the Box\u003c\/span\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cp\u003eExact shipped contents depend on the control and airflow options selected with the order. A complete standard KDT system configuration generally includes the following primary components:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhisperKOOL Mini Blow-Through evaporator\u003c\/li\u003e\n\u003cli\u003eWhisperKOOL 220V H.E. Mini condenser\u003c\/li\u003e\n\u003cli\u003eIntegrated evaporator condensate pump\u003c\/li\u003e\n\u003cli\u003eKDT digital display for the standard-control configuration\u003c\/li\u003e\n\u003cli\u003e50-foot KDT display cable for the standard-control configuration\u003c\/li\u003e\n\u003cli\u003e50-foot liquid-temperature bottle probe for the standard-control configuration\u003c\/li\u003e\n\u003cli\u003eEvaporator installation hardware and drain fittings\u003c\/li\u003e\n\u003cli\u003eInsulation components supplied for the evaporator and selected airflow accessories\u003c\/li\u003e\n\u003cli\u003eSelected Ducted, Ductless, or Hybrid Airflow Kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual and warranty documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNot Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant line set\u003c\/li\u003e\n\u003cli\u003eFinal refrigerant charge and commissioning labor\u003c\/li\u003e\n\u003cli\u003eHVAC-R installation labor\u003c\/li\u003e\n\u003cli\u003eElectrical branch circuits, disconnects, surge protection, or field wiring\u003c\/li\u003e\n\u003cli\u003eCustomer-supplied registers or decorative louvers\u003c\/li\u003e\n\u003cli\u003eField-supplied ductwork beyond the selected airflow plenums\u003c\/li\u003e\n\u003cli\u003eThird-party smart thermostat when the 24V conversion is selected\u003c\/li\u003e\n\u003cli\u003eWine-cellar construction, insulation, vapor barrier, framing, or finishing work\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-optional-addons\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eOptional Add-Ons\u003c\/span\u003e\n\u003ch2\u003eOptional Add-Ons\u003c\/h2\u003e\n\u003ch3\u003e24V Thermostat Conversion Kit\u003c\/h3\u003e\n\u003cp\u003eSelect this kit when the project requires a compatible customer-supplied third-party 24V thermostat. This option replaces the standard WhisperKOOL KDT controller and bottle-probe configuration. Third-party thermostat selection, setup, application support, networking, and troubleshooting are the purchaser's responsibility.\u003c\/p\u003e\n\u003ch3\u003eExterior Enclosure for the Omega Condenser\u003c\/h3\u003e\n\u003cp\u003eThe exterior enclosure is listed for Omega condenser applications that require outdoor protection. This accessory is associated with the Omega condenser option and is not normally required for the 220V H.E. condenser described on this product page.\u003c\/p\u003e\n\u003ch3\u003eDucting Kit for the Omega Condenser\u003c\/h3\u003e\n\u003cp\u003eThe Omega condenser ducting kit is intended for indoor Omega condenser installations that require condenser intake and exhaust ducting. It is not the evaporator airflow kit and should not be confused with the required Ducted, Ductless, or Hybrid Blow-Through airflow selection.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-maintenance\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eMaintenance\u003c\/span\u003e\n\u003ch2\u003eAnnual Maintenance Program\u003c\/h2\u003e\n\u003cp\u003eAnnual preventive maintenance is essential for long service life, dependable temperature control, efficient operation, and reduced risk of unscheduled cellar downtime. Service should be performed by a qualified technician familiar with wine cellar refrigeration equipment.\u003c\/p\u003e\n\u003ch3\u003eRecommended Maintenance Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInspect duct insulation and vapor-barrier integrity.\u003c\/li\u003e\n\u003cli\u003eClean supply and return registers.\u003c\/li\u003e\n\u003cli\u003eInspect and clean or replace the return-air filter.\u003c\/li\u003e\n\u003cli\u003eInspect evaporator and condenser coils for dirt, damage, fin deterioration, and refrigerant leaks.\u003c\/li\u003e\n\u003cli\u003eClean coils using appropriate non-damaging methods.\u003c\/li\u003e\n\u003cli\u003eInspect the drain pan, drain line, condensate pump reservoir, and water sensor.\u003c\/li\u003e\n\u003cli\u003eClear drain obstructions and perform a condensate drain test.\u003c\/li\u003e\n\u003cli\u003eInspect electrical connections, contactors, relays, and terminations.\u003c\/li\u003e\n\u003cli\u003eConfirm correct fan operation.\u003c\/li\u003e\n\u003cli\u003eMeasure equipment voltage and amperage.\u003c\/li\u003e\n\u003cli\u003eCheck refrigeration pressures, superheat, and subcooling.\u003c\/li\u003e\n\u003cli\u003eInspect the sight glass and moisture indicator.\u003c\/li\u003e\n\u003cli\u003eVerify controller-probe operation.\u003c\/li\u003e\n\u003cli\u003eClean the bottle probe and replace the water in the probe bottle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-warranty\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eWarranty\u003c\/span\u003e\n\u003ch2\u003eSplit-System Product Warranty\u003c\/h2\u003e\n\u003cp\u003eWhisperKOOL provides a limited 2-year product warranty for qualifying split systems, with up to one additional year of installation grace. The warranty period begins on the purchase date, but coverage is not activated until the required split-system warranty checklist has been completed, submitted, reviewed, and approved by WhisperKOOL.\u003c\/p\u003e\n\u003ch3\u003eWarranty Activation Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstallation by a qualified HVAC-R technician\u003c\/li\u003e\n\u003cli\u003eComplete installer and company information\u003c\/li\u003e\n\u003cli\u003eModel and serial numbers\u003c\/li\u003e\n\u003cli\u003eLine-set sizes, length, and vertical rise\u003c\/li\u003e\n\u003cli\u003eRefrigerant charge weight\u003c\/li\u003e\n\u003cli\u003ePressure and temperature readings\u003c\/li\u003e\n\u003cli\u003eSuperheat and subcooling measurements\u003c\/li\u003e\n\u003cli\u003eVoltage and amperage readings\u003c\/li\u003e\n\u003cli\u003eCondensate drainage test\u003c\/li\u003e\n\u003cli\u003eStartup date\u003c\/li\u003e\n\u003cli\u003eSubmission and approval of the official warranty checklist\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFailure to follow the installation manual, provide sufficient airflow, complete required insulation, use a qualified installer, or submit the warranty checklist may affect warranty coverage.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-resources\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eResources\u003c\/span\u003e\n\u003ch2\u003eResources \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Maintenance_Checklist_Blow_Through_Series.pdf?v=1785318338\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Series Maintenance Checklist\" target=\"_blank\"\u003e WhisperKOOL Blow-Through Series Maintenance Checklist \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Blow_Through_Series_Sales_Sheet_WEB.pdf?v=1785318338\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Series Sales Sheet\" target=\"_blank\"\u003e WhisperKOOL Blow-Through Series Sales Sheet \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Blow-Through_Configuration_Sheet.pdf?v=1785318341\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Configuration Sheet\" target=\"_blank\"\u003e Blow-Through Airflow Configuration Sheet \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_MINI_CHARGE_CHART.pdf?v=1785318341\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Mini Condenser Charge Chart\" target=\"_blank\"\u003e WhisperKOOL Mini Condenser Charge Chart \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/KDT-vs.-24V-Comp-Chart.pdf?v=1785318351\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL KDT versus 24V Thermostat Comparison Chart\" target=\"_blank\"\u003e KDT vs. 24V Thermostat Comparison Chart \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Blow-Through_Product_Sheet.pdf?v=1785318361\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Product Specification Sheet\" target=\"_blank\"\u003e Blow-Through Product Specification Sheet \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Mini_Condenser_QuickStartGuide.pdf?v=1785318361\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Mini Condenser Quick Start Guide\" target=\"_blank\"\u003e WhisperKOOL Mini Condenser Quick Start Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Register_Louver_Airflow_Requirements.pdf?v=1785318363\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Register and Louver Airflow Requirements\" target=\"_blank\"\u003e Register and Louver Airflow Requirements \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Blow_Through_Series_HE_OM.pdf?v=1785318428\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Series High Efficiency Owner's Manual\" target=\"_blank\"\u003e Blow-Through Series H.E. Owner's Manual \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Linear_Register_Ducting_Best_Practices.pdf?v=1785318516\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Linear Register Ducting Best Practices Guide\" target=\"_blank\"\u003e Linear Register Ducting Best Practices \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-faq\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eFAQ\u003c\/span\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat is the WhisperKOOL Mini Blow-Through?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eIt is a compact split-system wine cellar cooling system designed for concealed installations. The evaporator can use ducted, ductless, or hybrid airflow while a separate 220V H.E. condenser rejects heat remotely.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow large of a wine cellar can the Mini Blow-Through cool?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eWhisperKOOL lists the Mini Blow-Through for approximately 500 cubic feet when the cellar is fully insulated, tightly sealed, and protected by a proper vapor barrier. Glass, stone, concrete, exterior exposure, poor insulation, and other heat-load factors may require a larger system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eDoes the Mini Blow-Through require ductwork?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eNot necessarily. It can be ordered with a fully ducted kit, a ductless deflector kit, or a hybrid kit that combines one duct plenum with one deflector.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhich airflow kit is required?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eEvery system requires one airflow kit. Choose the Ducted Airflow Kit for two duct plenums, the Ductless Airflow Kit for two directional deflectors, or the Hybrid Airflow Kit for one duct plenum and one deflector.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat is the difference between ducted and ductless airflow?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eA fully ducted system connects both the return and supply to insulated ducts. A ductless system directs both air paths through deflectors near the evaporator. Hybrid airflow ducts one side while the other uses a deflector.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan the system be hidden in a soffit?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eYes. The Mini Blow-Through is designed for concealed soffit and similar installations when the structure supports the unit, required insulation is installed, supply and return openings are correctly planned, and adequate service access is maintained.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan it be used for a glass wine cellar?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eIt can be used in glass-enclosed wine cellar projects, but glass significantly increases cooling load. A professional heat-load calculation is essential, and the approximate 500-cubic-foot rating should not be used without accounting for the glass area and surrounding conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eIs the 220V condenser included?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThis product is described as the Mini Blow-Through system paired with the 220V H.E. condenser. Confirm the final order configuration and selected airflow kit before purchase.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eIs the refrigerant line set included?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eNo. The line set is not included and must be supplied, sized, installed, insulated, evacuated, pressure tested, and charged by the installing HVAC-R technician.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow far can the condenser be installed from the evaporator?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe condenser can be installed up to 100 line feet from the evaporator when the correct line diameters, oil-management practices, refrigerant charge, and commissioning procedures are used.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eDoes the evaporator have a condensate pump?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eYes. The evaporator includes an internal condensate pump. A drain line must still be connected, routed to an approved discharge location, and tested during installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat does the bottle probe do?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe standard KDT bottle probe measures the temperature of liquid inside a bottle rather than measuring only cellar air. Because liquid temperature changes more slowly than air temperature, it provides a more stable representation of wine-storage conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan I use a smart thermostat?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eA customer-supplied 24V smart thermostat can be used only when the optional 24V Thermostat Conversion Kit is selected. This removes the standard WhisperKOOL KDT control and bottle probe. WhisperKOOL does not provide technical support for third-party thermostats.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eIs a smart thermostat better than the KDT controller?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eNot necessarily. A smart thermostat may provide app access and home-automation compatibility, but the standard KDT controller includes WhisperKOOL-specific programming, liquid-temperature sensing, and wine-protection functions that a generic air-sensing thermostat may not reproduce.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eDoes this system require professional installation?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eYes. A qualified HVAC-R technician must install and commission the system. Professional installation is required for refrigerant piping, electrical connections, pressure testing, evacuation, charging, TXV adjustment, drainage testing, and warranty documentation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat refrigerant does the Mini Blow-Through use?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe current owner's manual specifications for the Mini Blow-Through H.E. system list R-134a refrigerant.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow much clearance is required around the equipment?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe evaporator requires at least 12 inches of front service access. The installation documentation also emphasizes unobstructed airflow and recommends substantial open space around the evaporator and condenser wherever possible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan decorative wood registers be used?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eYes, provided they meet the required airflow criteria. Customer-supplied registers should provide approximately 50%–65% free area and must not use restrictive screens, foam, mesh, or tightly spaced slats that reduce airflow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat happens if the registers are too restrictive?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eRestrictive registers can reduce capacity, increase airflow noise, raise static pressure, contribute to coil freezing, and shorten blower or system life. Insufficient register airflow may also affect warranty coverage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat size ducts are required for the Mini Blow-Through?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe Mini Blow-Through uses an 8-inch supply duct and an 8-inch return duct in fully ducted installations. The ducts must be insulated, properly supported, sealed, and protected by an exterior vapor barrier.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow often should the system be maintained?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eWhisperKOOL recommends annual preventive maintenance. The service should include airflow components, filters, coils, drainage, condensate pump operation, electrical connections, fan operation, refrigerant performance, controller probes, and the bottle probe.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow is the warranty activated?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe installer must complete and submit the split-system warranty checklist with the required installation, electrical, refrigerant, drainage, and startup data. The warranty is not active until WhisperKOOL reviews and approves the checklist.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection class=\"wce-final-guidance\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eExpert Guidance\u003c\/span\u003e\n\u003ch2\u003eImportant Ordering and Installation Guidance\u003c\/h2\u003e\n\u003cp\u003eBefore ordering the WhisperKOOL Mini Blow-Through 220V H.E. system, confirm the calculated cellar heat load, equipment voltage, condenser location, line-set route, drain route, evaporator access, register sizing, and required airflow kit with the professionals responsible for the wine-cellar design and refrigeration installation.\u003c\/p\u003e\n\u003cp\u003eThis system is designed to protect wine in a purpose-built storage environment. Its published capacity depends on correct cellar construction, unrestricted airflow, proper insulation, a continuous vapor barrier, accurate refrigerant charging, and ongoing preventive maintenance.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/section\u003e\n\u003cstyle\u003e\n.wce-product-page{max-width:1120px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#344047;line-height:1.62}.wce-product-page *{box-sizing:border-box}.wce-product-page\u003esection,.wce-product-header{padding:34px 40px;border-top:1px solid #ececed}.wce-product-header{border-top:none}.wce-product-page hr{display:none}.wce-product-page h1{font-size:32px;line-height:1.18;color:#300b05;margin:0 0 18px;font-weight:800}.wce-product-page h2{font-size:29px;line-height:1.2;color:#300b05;margin:0 0 14px}.wce-product-page h3{font-size:19px;line-height:1.3;color:#300b05;margin:24px 0 8px}.wce-product-page p{font-size:15px;margin:0 0 14px}.wce-product-intro{font-size:17px!important;color:#23150f}.wce-eyebrow,.wce-product-header .wce-eyebrow{display:inline-block;background:#5a1a0e;color:#fff;font-size:11px;font-weight:700;letter-spacing:.14em;text-transform:uppercase;padding:6px 15px;border-radius:30px;margin-bottom:14px}.wce-product-header\u003e.wce-eyebrow{background:#c8a24a;color:#300b05;font-weight:800}.wce-stats{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin:26px 0}.wce-stat{background:#43150d;border-radius:16px;padding:24px 14px;text-align:center;border-top:4px solid #a3bd04}.wce-stat-num{font-size:29px;font-weight:800;color:#fff;line-height:1;white-space:nowrap}.wce-stat-num small{font-size:14px}.wce-stat-lab{font-size:11px;text-transform:uppercase;letter-spacing:.06em;margin-top:9px;color:#c8a24a}.wce-important-notice{background:#f6f6f7;border:1px solid #c8a24a;border-left:5px solid #c8a24a;padding:18px 20px;border-radius:14px;margin:18px 0 0;color:#300b05;font-size:14px}.wce-ai-summary,.wce-airflow-configurations,.wce-controller-options,.wce-resources{background:#d4e29b;border:1px solid #a3bd04!important;border-radius:18px;margin:18px 0}.wce-not-recommended,.wce-airflow-warning{background:#fff;border:1px solid #e4e4e5!important;border-left:5px solid #c8a24a!important;border-radius:16px;margin:18px 0}.wce-table-wrap{width:100%;overflow-x:auto;border-radius:14px;border:1px solid #e4e4e5;margin:16px 0 4px}.wce-product-page table{width:100%;border-collapse:collapse;background:#fff}.wce-product-page thead th{background:#300b05;color:#fff;text-align:left;font-size:12px;letter-spacing:.04em;text-transform:uppercase;padding:14px 18px}.wce-product-page tbody th,.wce-product-page td{padding:14px 18px;border-bottom:1px solid #e4e4e5;font-size:14px;vertical-align:top;text-align:left}.wce-product-page tbody th{color:#300b05;width:36%;font-weight:700;border-right:1px solid #e4e4e5}.wce-product-page tbody tr:nth-child(odd){background:#f6f6f7}.wce-product-page tr:last-child td,.wce-product-page tr:last-child th{border-bottom:none}.wce-features h3,.wce-installation-requirements h3,.wce-optional-addons h3,.wce-maintenance h3,.wce-warranty h3{padding-left:14px;border-left:4px solid #a3bd04}.wce-product-page ul{margin:10px 0 16px;padding-left:22px}.wce-product-page li{margin:7px 0}.wce-included,.wce-optional-addons{display:block}.wce-resources ul{list-style:none;padding:0;margin:18px 0 0;display:grid;grid-template-columns:1fr 1fr;gap:10px}.wce-resources li{margin:0}.wce-resources a{display:flex;align-items:center;min-height:58px;background:#fff;border:1px solid #e4e4e5;border-radius:10px;padding:13px 16px;color:#300b05;text-decoration:none;font-weight:700;font-size:14px}.wce-resources a:before{content:\"↓\";display:inline-flex;align-items:center;justify-content:center;width:34px;height:34px;margin-right:12px;border-radius:9px;background:#300b05;color:#c8a24a;font-size:18px;flex:none}.wce-faq-item{background:#fff;border:1px solid #e4e4e5;border-radius:14px;margin-bottom:10px;overflow:hidden}.wce-faq-item summary{cursor:pointer;list-style:none;padding:16px 52px 16px 20px;font-weight:700;color:#300b05;position:relative;background:#f6f6f7}.wce-faq-item summary::-webkit-details-marker{display:none}.wce-faq-item summary:after{content:\"+\";position:absolute;right:18px;top:50%;transform:translateY(-50%);width:26px;height:26px;line-height:26px;text-align:center;border-radius:50%;background:#300b05;color:#fff}.wce-faq-item[open] summary{background:#300b05;color:#fff}.wce-faq-item[open] summary:after{content:\"−\";background:#c8a24a;color:#300b05}.wce-faq-body{padding:16px 20px}.wce-faq-body p{margin:0}.wce-final-guidance{background:#300b05!important;color:#fff;border-radius:18px;margin:18px 0 0;position:relative;overflow:hidden;text-align:center;padding:42px!important}.wce-final-guidance:before{content:\"\";position:absolute;left:0;top:0;width:100%;height:6px;background:linear-gradient(90deg,#c8a24a,#a3bd04,#c8a24a)}.wce-final-guidance .wce-eyebrow{background:#c8a24a;color:#300b05}.wce-final-guidance h2{color:#fff}.wce-final-guidance p{color:#e8cf93;max-width:820px;margin:0 auto 14px}.wce-product-page a{color:#5a1a0e}.wce-product-page strong{color:#300b05}@media(max-width:860px){.wce-stats{grid-template-columns:1fr 1fr}.wce-resources ul{grid-template-columns:1fr}.wce-product-page\u003esection,.wce-product-header{padding:28px 22px}}@media(max-width:560px){.wce-stats{grid-template-columns:1fr}.wce-product-page h1{font-size:27px}.wce-product-page h2{font-size:24px}.wce-product-page tbody th,.wce-product-page td{padding:12px 13px}.wce-final-guidance{padding:34px 20px!important}}\n\u003c\/style\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52125815374044,"sku":"S-WKBT-MINI-220","price":6625.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/whisperkool-mini-blow-through-220v-h-e-wine-cellar-cooling-system-s-wkbt-mini-220-wine-cellar-units-s-wkbt-mini-220-wine-coolers-empire-1251393965.webp?v=1785328090","url":"https:\/\/winecoolersempire.com\/products\/whisperkool-mini-blow-through-220v-he-wine-cellar-cooling-system","provider":"Wine Coolers Empire","version":"1.0","type":"link"}