{"product_id":"whisperkool-mini-ducted-airflow-kit-2-duct-plenums-03-ducted-kit-min","title":"WhisperKOOL Mini Ducted Airflow Kit with 2 Duct Plenums – 03-DUCTED-KIT-MIN","description":"\u003csection class=\"wce-product-page\"\u003e\u003cheader class=\"wce-product-header\"\u003e\n\u003cp class=\"wce-eyebrow\"\u003eWhisperKOOL Mini Blow-Through Airflow Accessory\u003c\/p\u003e\n\u003ch2\u003eWhisperKOOL Mini Ducted Airflow Kit with 2 Duct Plenums – 03-DUCTED-KIT-MIN\u003c\/h2\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\n\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eImportant Note:\u003c\/span\u003e\u003c\/strong\u003e This Add-on Accessory cannot be purchase without the Main Unit.\u003c\/h3\u003e\n\u003cp class=\"wce-product-intro\"\u003e \u003c\/p\u003e\n\u003cp class=\"wce-product-intro\"\u003eThe \u003cstrong\u003eWhisperKOOL Mini Ducted Airflow Kit\u003c\/strong\u003e, model \u003cstrong\u003e03-DUCTED-KIT-MIN\u003c\/strong\u003e, is designed specifically for a compatible \u003cstrong\u003eWhisperKOOL Mini Blow-Through evaporator\u003c\/strong\u003e. It includes two duct plenums that create a fully ducted airflow configuration: one plenum for the return-air side and one plenum for the conditioned supply-air side.\u003c\/p\u003e\n\u003cp\u003eThis model-specific accessory allows the Mini Blow-Through evaporator to be concealed away from the primary wine cellar display while insulated ductwork carries air between the evaporator and the cellar. It is suitable for custom wine rooms, glass-enclosed cellars, wine walls, cabinetry installations, soffits, and other projects where a clean architectural appearance is preferred.\u003c\/p\u003e\n\u003cdiv class=\"wce-stats\"\u003e\n\u003cdiv class=\"wce-stat\"\u003e\n\u003cdiv class=\"wce-stat-num\"\u003e2\u003csmall\u003e plenums\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat-lab\"\u003eMini supply and return\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat\"\u003e\n\u003cdiv class=\"wce-stat-num\"\u003e8\u003csmall\u003e in.\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat-lab\"\u003eSupply and return duct size\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat\"\u003e\n\u003cdiv class=\"wce-stat-num\"\u003e25\u003csmall\u003e ft.\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat-lab\"\u003eMaximum individual run\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat\"\u003e\n\u003cdiv class=\"wce-stat-num\"\u003e50\u003csmall\u003e ft.\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-stat-lab\"\u003eMaximum combined length\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-important-notice\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e The \u003cstrong\u003e03-DUCTED-KIT-MIN\u003c\/strong\u003e is an airflow accessory for the WhisperKOOL Mini Blow-Through evaporator. It is not a complete wine cellar cooling system and does not include the evaporator, condensing unit, field-installed ductwork, registers, refrigerant piping, electrical work, or installation labor.\u003c\/div\u003e\n\u003c\/header\u003e\n\u003csection class=\"wce-ai-summary\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eAt a Glance\u003c\/span\u003e\n\u003ch2\u003eProduct Summary\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eWhisperKOOL 03-DUCTED-KIT-MIN\u003c\/strong\u003e is a two-plenum airflow kit for the \u003cstrong\u003eMini Blow-Through evaporator\u003c\/strong\u003e. One duct plenum connects to the return-air side of the evaporator, while the second connects to the supply-air side. Together, they allow both airflow paths to be routed through separate insulated 8-inch ducts.\u003c\/p\u003e\n\u003cp\u003eThis fully ducted configuration is intended for wine cellar projects that require concealed equipment, remote supply and return registers, or greater flexibility in evaporator placement. Correct duct sizing, register free area, insulation, vapor sealing, fan configuration, and professional system commissioning are essential for proper performance.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-quick-specifications\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eSpecifications\u003c\/span\u003e\n\u003ch2\u003eQuick Product Specifications\u003c\/h2\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd\u003eWhisperKOOL Mini Ducted Airflow Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003e03-DUCTED-KIT-MIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eFully ducted airflow accessory kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible Evaporator\u003c\/th\u003e\n\u003ctd\u003eWhisperKOOL Mini Blow-Through evaporator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncluded Airflow Components\u003c\/th\u003e\n\u003ctd\u003e2 Mini duct plenums\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePlenum Configuration\u003c\/th\u003e\n\u003ctd\u003e1 return-air plenum and 1 supply-air plenum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRequired Duct Diameter\u003c\/th\u003e\n\u003ctd\u003e8-inch supply duct and 8-inch return duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAirflow Arrangement\u003c\/th\u003e\n\u003ctd\u003eFully ducted return and fully ducted supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Individual Duct Run\u003c\/th\u003e\n\u003ctd\u003eUp to 25 feet, subject to bends, fittings, compression, register design, and static pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Combined Duct Length\u003c\/th\u003e\n\u003ctd\u003eUp to 50 feet combined for the supply and return runs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eField-Installed Ductwork Included\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply and Return Registers Included\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling Equipment Included\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation Type\u003c\/th\u003e\n\u003ctd\u003eProfessional installation as part of a compatible Mini Blow-Through cooling system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-purpose\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eHow It Works\u003c\/span\u003e\n\u003ch2\u003eWhat Is the Mini Ducted Airflow Kit?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e03-DUCTED-KIT-MIN\u003c\/strong\u003e provides the two transition plenums required to connect a compatible WhisperKOOL Mini Blow-Through evaporator to field-installed supply and return ductwork.\u003c\/p\u003e\n\u003cp\u003eIn a fully ducted installation, warmer air from the wine cellar travels through an 8-inch return duct to the return-side plenum. The air then passes through the Mini evaporator, where heat is removed. Conditioned air leaves the evaporator through the supply-side plenum and travels through a separate 8-inch supply duct back into the cellar.\u003c\/p\u003e\n\u003cp\u003eThis configuration separates the supply and return airflow paths while allowing the evaporator to remain concealed in a properly designed and accessible installation location.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-configuration\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eAirflow Configuration\u003c\/span\u003e\n\u003ch2\u003eFully Ducted Mini Blow-Through Configuration\u003c\/h2\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAirflow Side\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn Air\u003c\/td\u003e\n\u003ctd\u003e8-inch return duct connected to the return-air plenum\u003c\/td\u003e\n\u003ctd\u003eDraws warmer wine cellar air back to the Mini Blow-Through evaporator.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Air\u003c\/td\u003e\n\u003ctd\u003e8-inch supply duct connected to the supply-air plenum\u003c\/td\u003e\n\u003ctd\u003eDelivers conditioned air from the Mini evaporator back into the wine cellar.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eBoth plenums are required for the fully ducted Mini configuration. The supply and return ducts must remain separate and should terminate at properly positioned cellar registers that provide adequate open area.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-key-benefits\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eKey Advantages\u003c\/span\u003e\n\u003ch2\u003eKey Benefits of the 03-DUCTED-KIT-MIN\u003c\/h2\u003e\n\u003ch3\u003eDesigned Specifically for the Mini Blow-Through Evaporator\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e03-DUCTED-KIT-MIN\u003c\/strong\u003e is intended for the physical dimensions and 8-inch duct requirements of the WhisperKOOL Mini Blow-Through evaporator. It should not be treated as interchangeable with ducted kits designed for larger Blow-Through models.\u003c\/p\u003e\n\u003ch3\u003eConceals the Evaporator\u003c\/h3\u003e\n\u003cp\u003eThe dual-plenum arrangement allows the evaporator to be installed outside the primary cellar sightline while only the supply and return registers remain visible within the wine room.\u003c\/p\u003e\n\u003ch3\u003eSupports Remote Register Placement\u003c\/h3\u003e\n\u003cp\u003eSupply and return air can be routed to selected locations within the cellar rather than being discharged directly beside the evaporator. This gives the project team more flexibility when planning airflow around wine racks, cabinetry, glass panels, doors, and lighting.\u003c\/p\u003e\n\u003ch3\u003eCreates Separate Supply and Return Paths\u003c\/h3\u003e\n\u003cp\u003eOne plenum is dedicated to return air and the other to conditioned supply air. Proper separation of the two cellar openings helps promote circulation and reduce immediate recirculation between the supply and return.\u003c\/p\u003e\n\u003ch3\u003eSupports a Clean Architectural Appearance\u003c\/h3\u003e\n\u003cp\u003eConcealing the Mini evaporator keeps attention on the wine display, custom millwork, racking, lighting, and architectural finishes rather than on the cooling equipment.\u003c\/p\u003e\n\u003ch3\u003eOffers Greater Installation Flexibility\u003c\/h3\u003e\n\u003cp\u003eSubject to the complete installation requirements, the evaporator may be located in a soffit, adjacent conditioned space, accessible cabinet cavity, mechanical area, or another suitable location connected to the cellar through correctly designed ducts.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-applications\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eBest Applications\u003c\/span\u003e\n\u003ch2\u003eRecommended Applications\u003c\/h2\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003cth\u003eHow the Mini Ducted Kit Supports the Project\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom residential wine cellars\u003c\/td\u003e\n\u003ctd\u003eAllows the Mini evaporator to remain concealed while separate registers deliver and return air.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass-enclosed wine rooms\u003c\/td\u003e\n\u003ctd\u003eHelps preserve clean visual lines by keeping the evaporator away from the primary display area.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWine walls\u003c\/td\u003e\n\u003ctd\u003eSupports remote airflow delivery where there may be limited room to expose cooling equipment directly inside the enclosure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in wine cabinetry\u003c\/td\u003e\n\u003ctd\u003eAllows airflow to be routed through planned openings while the evaporator remains in an accessible service location.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeiling or soffit installations\u003c\/td\u003e\n\u003ctd\u003eConnects a concealed Mini evaporator to separate cellar supply and return registers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjacent mechanical spaces\u003c\/td\u003e\n\u003ctd\u003eAllows the evaporator to serve the wine cellar through ductwork without occupying visible cellar wall space.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRestaurant wine displays\u003c\/td\u003e\n\u003ctd\u003eHelps keep mechanical equipment discreet in customer-facing storage and presentation areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHospitality wine storage\u003c\/td\u003e\n\u003ctd\u003eSupports professionally planned airflow in tasting rooms, storage rooms, and display cellars.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-buyer-fit\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eBuyer Fit\u003c\/span\u003e\n\u003ch2\u003eWho Should Choose the Mini Ducted Airflow Kit?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e03-DUCTED-KIT-MIN\u003c\/strong\u003e is appropriate when a project uses a WhisperKOOL Mini Blow-Through evaporator and both the return and supply sides must connect to ductwork.\u003c\/p\u003e\n\u003ch3\u003eThis Kit Is a Strong Fit When:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe project uses a compatible WhisperKOOL Mini Blow-Through evaporator.\u003c\/li\u003e\n\u003cli\u003eThe evaporator must remain hidden from normal view.\u003c\/li\u003e\n\u003cli\u003eBoth supply and return air need to be routed remotely.\u003c\/li\u003e\n\u003cli\u003eThere is enough space for separate 8-inch supply and return ducts.\u003c\/li\u003e\n\u003cli\u003eThe duct routes can remain reasonably short, smooth, and unrestricted.\u003c\/li\u003e\n\u003cli\u003eThe cellar can accommodate properly sized supply and return registers.\u003c\/li\u003e\n\u003cli\u003eThe installation team can provide adequate insulation and vapor sealing.\u003c\/li\u003e\n\u003cli\u003eThe evaporator location will remain accessible for service and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThis Kit May Not Be Appropriate When:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe installed evaporator is a Blow-Through 4000 or 8000 rather than a Mini.\u003c\/li\u003e\n\u003cli\u003eOnly one side of the evaporator needs to be ducted.\u003c\/li\u003e\n\u003cli\u003eThe evaporator can connect directly to the cellar without supply or return ducts.\u003c\/li\u003e\n\u003cli\u003eThere is not enough space for two correctly sized 8-inch ducts.\u003c\/li\u003e\n\u003cli\u003eThe proposed duct routes require excessive length, sharp bends, or compressed flexible duct.\u003c\/li\u003e\n\u003cli\u003eThe cellar design cannot provide registers with sufficient free area.\u003c\/li\u003e\n\u003cli\u003eThe evaporator would be enclosed without suitable service access.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-compatibility\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eCompatibility\u003c\/span\u003e\n\u003ch2\u003eMini Blow-Through Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e03-DUCTED-KIT-MIN\u003c\/strong\u003e is designed specifically for the \u003cstrong\u003eWhisperKOOL Mini Blow-Through evaporator\u003c\/strong\u003e. The Mini configuration uses an 8-inch supply duct and an 8-inch return duct.\u003c\/p\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eCompatibility Requirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaporator\u003c\/td\u003e\n\u003ctd\u003eCompatible WhisperKOOL Mini Blow-Through evaporator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Plenum\u003c\/td\u003e\n\u003ctd\u003eMini-specific plenum included with the 03-DUCTED-KIT-MIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn Plenum\u003c\/td\u003e\n\u003ctd\u003eMini-specific plenum included with the 03-DUCTED-KIT-MIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Duct\u003c\/td\u003e\n\u003ctd\u003e8-inch insulated duct supplied separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn Duct\u003c\/td\u003e\n\u003ctd\u003e8-inch insulated duct supplied separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegisters\u003c\/td\u003e\n\u003ctd\u003eCustomer-supplied registers sized to provide adequate airflow and free area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wce-important-notice\"\u003e\n\u003cstrong\u003eCompatibility notice:\u003c\/strong\u003e Confirm that the evaporator is the WhisperKOOL Mini Blow-Through model before ordering. The \u003cstrong\u003e03-DUCTED-KIT-MIN\u003c\/strong\u003e is not the ducted airflow kit for the larger Blow-Through 4000 or 8000 evaporators.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-duct-requirements\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eDuct Planning\u003c\/span\u003e\n\u003ch2\u003eMini Ductwork Requirements\u003c\/h2\u003e\n\u003cp\u003eThe two plenums serve as the connection points between the Mini Blow-Through evaporator and the field-installed duct system. The installer must separately provide the 8-inch supply duct, 8-inch return duct, fittings, supports, insulation, vapor barrier, sealants, registers, and other project-specific materials.\u003c\/p\u003e\n\u003ch3\u003eRequired Duct Configuration\u003c\/h3\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Duct Diameter\u003c\/th\u003e\n\u003ctd\u003e8 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReturn Duct Diameter\u003c\/th\u003e\n\u003ctd\u003e8 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply and Return Arrangement\u003c\/th\u003e\n\u003ctd\u003eSeparate ducts connected to separate plenums\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Individual Duct Length\u003c\/th\u003e\n\u003ctd\u003eUp to 25 feet under suitable installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Combined Length\u003c\/th\u003e\n\u003ctd\u003eUp to 50 feet for the supply and return ducts combined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum 90-Degree Bends\u003c\/th\u003e\n\u003ctd\u003eNo more than two on an individual duct run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003ePublished duct-length values are maximum guidelines, not guaranteed acceptable lengths for every project. Bends, transitions, compressed flexible duct, restrictive registers, internal duct roughness, and other sources of static pressure can require shorter runs.\u003c\/p\u003e\n\u003ch3\u003eRecommended Ducting Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse 8-inch ductwork on both the supply and return sides.\u003c\/li\u003e\n\u003cli\u003eDo not reduce the duct diameter below the specified size.\u003c\/li\u003e\n\u003cli\u003eKeep both duct runs as short and straight as practical.\u003c\/li\u003e\n\u003cli\u003eUse sweeping turns instead of tight elbows.\u003c\/li\u003e\n\u003cli\u003eAvoid unnecessary transitions, branches, dampers, and restrictive fittings.\u003c\/li\u003e\n\u003cli\u003eFully extend flexible ductwork rather than leaving it compressed.\u003c\/li\u003e\n\u003cli\u003eSupport flexible ductwork to prevent sagging and internal restriction.\u003c\/li\u003e\n\u003cli\u003eDo not allow framing, stored materials, or insulation to crush the ducts.\u003c\/li\u003e\n\u003cli\u003eSeal all duct joints and plenum connections.\u003c\/li\u003e\n\u003cli\u003eInsulate both supply and return ducts.\u003c\/li\u003e\n\u003cli\u003eMaintain a continuous exterior vapor barrier around insulated ductwork.\u003c\/li\u003e\n\u003cli\u003eKeep the supply and return registers sufficiently separated inside the cellar.\u003c\/li\u003e\n\u003cli\u003eConfirm airflow after the complete system has been installed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach bend and fitting adds resistance to airflow. The supplied WhisperKOOL documentation notes that a 90-degree bend can reduce available airflow, making careful duct routing important for system performance.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-register-requirements\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eAirflow Requirements\u003c\/span\u003e\n\u003ch2\u003eSupply and Return Register Requirements\u003c\/h2\u003e\n\u003cp\u003eSupply and return registers are not included with the \u003cstrong\u003e03-DUCTED-KIT-MIN\u003c\/strong\u003e. The selected registers must provide enough open area for the Mini Blow-Through system to move air without excessive restriction.\u003c\/p\u003e\n\u003cp\u003eRegister size alone does not determine airflow capability. Decorative blades, narrow slots, backing plates, insect screens, mesh, filters, and trim can substantially reduce the usable free area.\u003c\/p\u003e\n\u003ch3\u003eRegister Planning Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvide approximately 50%–65% free area across the usable register face.\u003c\/li\u003e\n\u003cli\u003eAvoid decorative registers with tightly spaced or heavily angled blades.\u003c\/li\u003e\n\u003cli\u003eDo not add restrictive mesh, foam, screening, or solid backing.\u003c\/li\u003e\n\u003cli\u003eMaintain consistent openings across linear register faces.\u003c\/li\u003e\n\u003cli\u003eConfirm the finished free area before custom registers are fabricated.\u003c\/li\u003e\n\u003cli\u003eDo not allow paint, stain, trim, or sealant to reduce the register openings.\u003c\/li\u003e\n\u003cli\u003eKeep supply and return registers clear of bottles, boxes, racks, doors, and furniture.\u003c\/li\u003e\n\u003cli\u003ePlace the supply and return far enough apart to reduce immediate recirculation.\u003c\/li\u003e\n\u003cli\u003eUse an appropriate return-air filter arrangement where required by the installation documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRestrictive registers can reduce cooling performance, increase airflow noise, increase static pressure, contribute to evaporator-coil freezing, and place unnecessary stress on the cooling system.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-airflow-planning\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eAir Distribution\u003c\/span\u003e\n\u003ch2\u003eSupply and Return Airflow Planning\u003c\/h2\u003e\n\u003cp\u003eThe supply register delivers conditioned air into the wine cellar, while the return register draws warmer air back toward the Mini evaporator. Their positions should encourage circulation across the full wine-storage space rather than allowing supply air to travel directly into the return opening.\u003c\/p\u003e\n\u003ch3\u003eSupply-Air Placement\u003c\/h3\u003e\n\u003cp\u003eSupply air is commonly introduced from a higher wall or ceiling position so that conditioned air can circulate through the cellar. The exact location should account for the room dimensions, wine racks, glass surfaces, doors, lighting, and other heat sources.\u003c\/p\u003e\n\u003ch3\u003eReturn-Air Placement\u003c\/h3\u003e\n\u003cp\u003eThe return opening should be positioned where it can collect warmer cellar air without being blocked by wine bottles, cases, racks, cabinetry, or decorative finishes.\u003c\/p\u003e\n\u003ch3\u003eAvoid Airflow Short Cycling\u003c\/h3\u003e\n\u003cp\u003eShort cycling can occur when conditioned supply air is drawn directly back into the return before it circulates through the cellar. Adequate separation and thoughtful register orientation help establish a more effective airflow path.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-insulation\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eCondensation Control\u003c\/span\u003e\n\u003ch2\u003ePlenum, Duct, and Vapor-Barrier Requirements\u003c\/h2\u003e\n\u003cp\u003eThe plenums and connected ducts carry air at temperatures that may be below the dew point of surrounding warm or humid spaces. Proper insulation and vapor sealing are therefore necessary to reduce condensation risk.\u003c\/p\u003e\n\u003cp\u003eThe plenums must be insulated according to the official Mini Blow-Through installation instructions. Field-installed supply and return ducts must also be insulated and protected with a continuous exterior vapor barrier.\u003c\/p\u003e\n\u003ch3\u003eInsulation Checklist\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the specified insulation around both Mini duct plenums.\u003c\/li\u003e\n\u003cli\u003eInsulate the entire supply duct.\u003c\/li\u003e\n\u003cli\u003eInsulate the entire return duct.\u003c\/li\u003e\n\u003cli\u003eUse insulation with an exterior vapor-retarding jacket.\u003c\/li\u003e\n\u003cli\u003eSeal insulation seams, joints, and penetrations.\u003c\/li\u003e\n\u003cli\u003eSeal the duct-to-plenum connections.\u003c\/li\u003e\n\u003cli\u003eDo not leave exposed cold metal surfaces in warm or humid cavities.\u003c\/li\u003e\n\u003cli\u003eInsulate the evaporator installation area as required by the owner's manual.\u003c\/li\u003e\n\u003cli\u003eInspect the completed installation for gaps before enclosing the equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIncomplete insulation or vapor sealing can cause condensation, water damage, corrosion, reduced cooling performance, and damage to nearby finishes or building materials.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-installation\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eInstallation\u003c\/span\u003e\n\u003ch2\u003eInstallation Overview\u003c\/h2\u003e\n\u003cp\u003eInstallation of the \u003cstrong\u003e03-DUCTED-KIT-MIN\u003c\/strong\u003e must be coordinated with the complete Mini Blow-Through cooling-system installation. The plenum orientation, duct routes, evaporator support, refrigeration piping, condensate drainage, control wiring, power requirements, insulation, and service access should be planned before the evaporator is enclosed.\u003c\/p\u003e\n\u003ch3\u003eGeneral Installation Sequence\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the evaporator is a compatible WhisperKOOL Mini Blow-Through model.\u003c\/li\u003e\n\u003cli\u003eVerify that the accessory model is \u003cstrong\u003e03-DUCTED-KIT-MIN\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eInspect both Mini duct plenums and supplied components for damage.\u003c\/li\u003e\n\u003cli\u003eIdentify the return-air and supply-air sides of the evaporator.\u003c\/li\u003e\n\u003cli\u003ePlan separate 8-inch supply and return duct routes.\u003c\/li\u003e\n\u003cli\u003eDetermine the final supply and return register locations.\u003c\/li\u003e\n\u003cli\u003eVerify that the proposed register designs provide adequate free area.\u003c\/li\u003e\n\u003cli\u003ePrepare and insulate the evaporator as required by the official manual.\u003c\/li\u003e\n\u003cli\u003eAttach one Mini plenum to the return-air side.\u003c\/li\u003e\n\u003cli\u003eAttach the second Mini plenum to the supply-air side.\u003c\/li\u003e\n\u003cli\u003eInstall the required plenum insulation.\u003c\/li\u003e\n\u003cli\u003eConnect the insulated 8-inch supply and return ducts.\u003c\/li\u003e\n\u003cli\u003eSeal all duct-to-plenum connections.\u003c\/li\u003e\n\u003cli\u003eSupport the ducts independently so their weight does not pull on the plenums.\u003c\/li\u003e\n\u003cli\u003eInstall the cellar supply and return registers.\u003c\/li\u003e\n\u003cli\u003eConfigure the evaporator fan for fully ducted operation according to the official instructions.\u003c\/li\u003e\n\u003cli\u003eCommission the complete system and verify airflow at both cellar openings.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cdiv class=\"wce-important-notice\"\u003e\n\u003cstrong\u003eProfessional-installation notice:\u003c\/strong\u003e This overview does not replace the official WhisperKOOL installation and owner's manuals. Installation and commissioning of the complete split cooling system must be performed by a qualified HVAC-R technician.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-service-access\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eService Planning\u003c\/span\u003e\n\u003ch2\u003eService-Access Requirements\u003c\/h2\u003e\n\u003cp\u003eConcealing the Mini evaporator does not eliminate the need for future service access. The finished installation must allow qualified technicians to inspect and service the evaporator, plenums, drain system, refrigeration connections, electrical components, controls, and duct connections.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvide an appropriately sized access panel.\u003c\/li\u003e\n\u003cli\u003eDo not permanently seal the evaporator behind drywall or millwork.\u003c\/li\u003e\n\u003cli\u003eEnsure that access is not blocked by wine racks or stored cases.\u003c\/li\u003e\n\u003cli\u003eAllow room to inspect and clean the return-air filter.\u003c\/li\u003e\n\u003cli\u003eAllow access to both plenum connections.\u003c\/li\u003e\n\u003cli\u003eProvide access to the condensate-drain components.\u003c\/li\u003e\n\u003cli\u003eMaintain access to electrical and control connections.\u003c\/li\u003e\n\u003cli\u003eProvide enough working room for future repair or component replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-included\"\u003e\u003cspan class=\"wce-eyebrow\"\u003ePackage Contents\u003c\/span\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne Mini return-air duct plenum\u003c\/li\u003e\n\u003cli\u003eOne Mini supply-air duct plenum\u003c\/li\u003e\n\u003cli\u003eTwo Mini-specific plenum components for a fully ducted configuration\u003c\/li\u003e\n\u003cli\u003eApplicable plenum insulation components supplied for the Mini ducted arrangement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eReview the packing slip and official installation documentation upon delivery. Packaged hardware or component details may be subject to the manufacturer's current production configuration.\u003c\/p\u003e\n\u003ch3\u003eWhat's Not Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhisperKOOL Mini Blow-Through evaporator\u003c\/li\u003e\n\u003cli\u003eMatching condensing unit\u003c\/li\u003e\n\u003cli\u003eRefrigerant line set\u003c\/li\u003e\n\u003cli\u003eRefrigerant\u003c\/li\u003e\n\u003cli\u003e8-inch supply duct\u003c\/li\u003e\n\u003cli\u003e8-inch return duct\u003c\/li\u003e\n\u003cli\u003eDuct elbows, transitions, branches, or dampers\u003c\/li\u003e\n\u003cli\u003eDuct supports and suspension materials\u003c\/li\u003e\n\u003cli\u003eSupply register\u003c\/li\u003e\n\u003cli\u003eReturn register or grille\u003c\/li\u003e\n\u003cli\u003eCustom linear registers\u003c\/li\u003e\n\u003cli\u003eWine cellar construction materials\u003c\/li\u003e\n\u003cli\u003eSoffit, cabinet, or mechanical-room framing\u003c\/li\u003e\n\u003cli\u003eElectrical wiring or electrical labor\u003c\/li\u003e\n\u003cli\u003eRefrigeration installation materials\u003c\/li\u003e\n\u003cli\u003eHVAC-R installation or commissioning labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-comparison\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eConfiguration Comparison\u003c\/span\u003e\n\u003ch2\u003eMini Ducted vs. Ductless vs. Hybrid Airflow\u003c\/h2\u003e\n\u003cdiv class=\"wce-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eAirflow Arrangement\u003c\/th\u003e\n\u003cth\u003eBest Used When\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMini Ducted Airflow Kit\u003c\/td\u003e\n\u003ctd\u003eBoth return and supply air are routed through separate ducts.\u003c\/td\u003e\n\u003ctd\u003eThe Mini evaporator must be concealed and both airflow paths require remote routing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMini Ductless Airflow Configuration\u003c\/td\u003e\n\u003ctd\u003eReturn and supply air connect directly to the cellar without field-installed airflow ducts.\u003c\/td\u003e\n\u003ctd\u003eThe evaporator can be placed directly adjacent to the cellar openings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMini Hybrid Airflow Configuration\u003c\/td\u003e\n\u003ctd\u003eOne side is ducted while the other connects directly to the cellar.\u003c\/td\u003e\n\u003ctd\u003eOnly the supply or return side requires remote routing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eChoose the \u003cstrong\u003e03-DUCTED-KIT-MIN\u003c\/strong\u003e only when the project requires both sides of the Mini Blow-Through evaporator to be connected to ductwork.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-not-recommended\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eSelection Guidance\u003c\/span\u003e\n\u003ch2\u003eNot Recommended If\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eYou are installing a WhisperKOOL Blow-Through 4000 or 8000 evaporator.\u003c\/li\u003e\n\u003cli\u003eYou need only one duct plenum.\u003c\/li\u003e\n\u003cli\u003eYour project requires a ductless or hybrid airflow configuration.\u003c\/li\u003e\n\u003cli\u003eThere is not enough space for separate 8-inch supply and return ducts.\u003c\/li\u003e\n\u003cli\u003eThe ductwork would need to be sharply bent, crushed, or significantly reduced.\u003c\/li\u003e\n\u003cli\u003eThe proposed registers cannot provide sufficient open area.\u003c\/li\u003e\n\u003cli\u003eThe evaporator location cannot be properly insulated.\u003c\/li\u003e\n\u003cli\u003eThe evaporator would not remain accessible for maintenance.\u003c\/li\u003e\n\u003cli\u003eThe cooling system has not been selected through an appropriate cellar heat-load and sizing process.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-maintenance\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eMaintenance\u003c\/span\u003e\n\u003ch2\u003eMaintenance Considerations\u003c\/h2\u003e\n\u003cp\u003eThe Mini plenums and connected duct system should be inspected as part of routine maintenance for the complete Blow-Through cooling system. Airflow restrictions or insulation failures can affect performance even when the refrigeration system is operating normally.\u003c\/p\u003e\n\u003ch3\u003eRecommended Inspection Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInspect both plenums for damage or loose connections.\u003c\/li\u003e\n\u003cli\u003eInspect supply and return ducts for crushing, sagging, or disconnection.\u003c\/li\u003e\n\u003cli\u003eCheck all duct supports.\u003c\/li\u003e\n\u003cli\u003eInspect insulation for gaps, tears, or moisture damage.\u003c\/li\u003e\n\u003cli\u003eInspect vapor-barrier seams and sealed penetrations.\u003c\/li\u003e\n\u003cli\u003eClean the supply register.\u003c\/li\u003e\n\u003cli\u003eClean the return register or grille.\u003c\/li\u003e\n\u003cli\u003eClean or replace the return-air filter as required.\u003c\/li\u003e\n\u003cli\u003eRemove any bottles, cases, or furnishings blocking airflow.\u003c\/li\u003e\n\u003cli\u003eCheck for condensation around the plenums, ducts, and registers.\u003c\/li\u003e\n\u003cli\u003eVerify airflow from the supply register.\u003c\/li\u003e\n\u003cli\u003eVerify that air returns freely through the return register.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-resources\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eDocuments\u003c\/span\u003e\n\u003ch2\u003eResources \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Blow_Through_Series_Sales_Sheet_WEB.pdf?v=1785318338\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Series Sales Sheet\" target=\"_blank\"\u003e WhisperKOOL Blow-Through Series Sales Sheet \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Blow-Through_Configuration_Sheet.pdf?v=1785318341\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Airflow Configuration Sheet\" target=\"_blank\"\u003e WhisperKOOL Blow-Through Airflow Configuration Sheet \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Blow-Through_Product_Sheet.pdf?v=1785318361\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Product Sheet\" target=\"_blank\"\u003e WhisperKOOL Blow-Through Product Sheet \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Register_Louver_Airflow_Requirements.pdf?v=1785318363\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Register and Louver Airflow Requirements\" target=\"_blank\"\u003e Register and Louver Airflow Requirements \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Blow_Through_Series_HE_OM.pdf?v=1785318428\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Series High Efficiency Owner's Manual\" target=\"_blank\"\u003e WhisperKOOL Blow-Through Series H.E. Owner's Manual \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/Linear_Register_Ducting_Best_Practices.pdf?v=1785318516\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Linear Register Ducting Best Practices Guide\" target=\"_blank\"\u003e WhisperKOOL Linear Register Ducting Best Practices \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WK_Maintenance_Checklist_Blow_Through_Series.pdf?v=1785318338\" rel=\"noopener noreferrer\" title=\"Download the WhisperKOOL Blow-Through Series Maintenance Checklist\" target=\"_blank\"\u003e WhisperKOOL Blow-Through Series Maintenance Checklist \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-faq\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eFAQ\u003c\/span\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat is the WhisperKOOL 03-DUCTED-KIT-MIN?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eIt is a fully ducted airflow accessory kit for a compatible WhisperKOOL Mini Blow-Through evaporator. It provides two duct plenums: one for return air and one for conditioned supply air.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow many duct plenums are included?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe Mini Ducted Airflow Kit includes two plenums. One connects to the return-air side of the evaporator, and the other connects to the supply-air side.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eIs the 03-DUCTED-KIT-MIN a complete cooling system?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eNo. It is an airflow accessory only. The Mini Blow-Through evaporator, condenser, refrigerant piping, ductwork, registers, electrical work, and installation labor are not included.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhich evaporator is compatible with this kit?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe kit is designed for a compatible WhisperKOOL Mini Blow-Through evaporator. It is not the ducted kit for the larger Blow-Through 4000 or 8000 models.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat duct size does the Mini Ducted Airflow Kit require?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe Mini fully ducted configuration uses a separate 8-inch supply duct and 8-inch return duct.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eAre the 8-inch ducts included?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eNo. The kit provides the two Mini duct plenums. The insulated 8-inch supply and return ducts must be supplied and installed separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eAre supply and return registers included?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eNo. Cellar registers or grilles are supplied separately and must be sized to provide adequate airflow and open area.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat does fully ducted mean?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eFully ducted means that both the return-air side and supply-air side of the Mini evaporator are connected to separate ducts. Air returns from the cellar through one duct and conditioned air travels back through the other.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan this kit conceal the Mini Blow-Through evaporator?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eYes. A fully ducted configuration can allow the evaporator to be installed outside the primary cellar sightline, provided the location satisfies all insulation, drainage, airflow, structural, and service-access requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan the evaporator be installed in a soffit?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eIt may be installed in a properly designed soffit when the complete installation meets the manufacturer's requirements for structural support, insulation, vapor sealing, drainage, airflow, and service access.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow long can the Mini supply and return ducts be?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe supplied guidance provides a maximum of up to 25 feet for an individual run and up to 50 feet for the supply and return combined. Actual acceptable lengths may be shorter when bends, restrictions, compression, or restrictive registers are present.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow many 90-degree bends can each duct have?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eNo more than two 90-degree bends should be used on an individual duct run. Broad, sweeping turns are preferred because sharp bends increase resistance and reduce airflow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan flexible ductwork be used?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eFlexible duct may be used when it is correctly sized, insulated, fully extended, sealed, and supported. It must not be crushed, compressed, sharply bent, or allowed to sag.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan the 8-inch duct be reduced to a smaller diameter?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eReducing the specified duct diameter can increase static pressure and reduce airflow. The duct system should maintain the required 8-inch diameter unless an approved system design specifically states otherwise.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eDo the Mini duct plenums require insulation?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eYes. The plenums must be insulated according to the official installation instructions. The connected supply and return ducts must also be insulated and vapor sealed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow much free area should the cellar registers provide?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eCustomer-supplied registers should generally provide approximately 50%–65% free area across the usable face. Decorative blades, mesh, screens, and backing can substantially reduce that area.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhy must the supply and return registers be separated?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eSeparation helps conditioned air circulate through the wine cellar before returning to the evaporator. Registers installed too close together can cause immediate recirculation and uneven cellar conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan this kit be used for a glass wine cellar?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eIt can be used as part of a properly designed glass-cellar cooling system. However, glass can substantially increase the cooling load, so equipment selection must be based on a project-specific heat-load calculation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eDoes the ducted configuration affect cooling performance?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eDucts, bends, fittings, and registers add resistance to airflow. Cooling-system sizing and performance evaluation should therefore use the applicable fully ducted data for the Mini Blow-Through system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eWhat fan configuration should be used?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eThe evaporator fan must be configured for fully ducted operation according to the official WhisperKOOL installation instructions. The installing technician should verify airflow during system commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eDoes the Mini Ducted Airflow Kit require professional installation?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eYes. It should be installed as part of a professionally planned Mini Blow-Through system. The complete split refrigeration system must be installed and commissioned by a qualified HVAC-R technician.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eHow do I know whether I need the ducted or hybrid Mini kit?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eChoose the ducted kit when both supply and return air must travel through ducts. Choose a hybrid configuration when only one side requires ducting and the other side connects directly to the cellar.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wce-faq-item\"\u003e\n\u003csummary\u003eCan the 03-DUCTED-KIT-MIN be used with the Blow-Through 4000 or 8000?\u003c\/summary\u003e\n\u003cdiv class=\"wce-faq-body\"\u003e\n\u003cp\u003eNo. The \u003cstrong\u003e03-DUCTED-KIT-MIN\u003c\/strong\u003e is specific to the Mini Blow-Through configuration. The 4000 and 8000 models use different airflow components and larger duct connections.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\n\u003csection class=\"wce-final-guidance\"\u003e\u003cspan class=\"wce-eyebrow\"\u003eExpert Guidance\u003c\/span\u003e\n\u003ch2\u003eImportant Ordering Guidance\u003c\/h2\u003e\n\u003cp\u003eBefore ordering the \u003cstrong\u003eWhisperKOOL Mini Ducted Airflow Kit 03-DUCTED-KIT-MIN\u003c\/strong\u003e, confirm that the cooling project uses a compatible Mini Blow-Through evaporator and requires both the supply and return sides to be fully ducted.\u003c\/p\u003e\n\u003cp\u003eThe project team should also verify that there is sufficient space for separate 8-inch ducts, properly sized cellar registers, complete insulation, vapor sealing, condensate management, and future service access.\u003c\/p\u003e\n\u003cp\u003eCorrect model selection, duct design, register free area, installation quality, and system commissioning are essential. The ducted airflow kit does not increase the cooling capacity of an undersized system and does not replace the need for a wine cellar heat-load calculation.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/section\u003e\n\u003cstyle\u003e\n.wce-product-page{max-width:1120px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#344047;line-height:1.62}.wce-product-page *{box-sizing:border-box}.wce-product-page\u003esection,.wce-product-header{padding:34px 40px;border-top:1px solid #ececed}.wce-product-header{border-top:none}.wce-product-page h1{font-size:32px;line-height:1.18;color:#300b05;margin:0 0 18px;font-weight:800}.wce-product-page h2{font-size:29px;line-height:1.2;color:#300b05;margin:0 0 14px}.wce-product-page h3{font-size:19px;line-height:1.3;color:#300b05;margin:24px 0 8px}.wce-product-page p{font-size:15px;margin:0 0 14px}.wce-product-intro{font-size:17px!important;color:#23150f}.wce-eyebrow,.wce-product-header .wce-eyebrow{display:inline-block;background:#5a1a0e;color:#fff;font-size:11px;font-weight:700;letter-spacing:.14em;text-transform:uppercase;padding:6px 15px;border-radius:30px;margin-bottom:14px}.wce-product-header\u003e.wce-eyebrow{background:#c8a24a;color:#300b05;font-weight:800}.wce-stats{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin:26px 0}.wce-stat{background:#43150d;border-radius:16px;padding:24px 14px;text-align:center;border-top:4px solid #a3bd04}.wce-stat-num{font-size:29px;font-weight:800;color:#fff;line-height:1;white-space:nowrap}.wce-stat-num small{font-size:14px}.wce-stat-lab{font-size:11px;text-transform:uppercase;letter-spacing:.06em;margin-top:9px;color:#c8a24a}.wce-important-notice{background:#f6f6f7;border:1px solid #c8a24a;border-left:5px solid #c8a24a;padding:18px 20px;border-radius:14px;margin:18px 0 0;color:#300b05;font-size:14px}.wce-ai-summary,.wce-configuration,.wce-compatibility,.wce-comparison,.wce-resources{background:#d4e29b;border:1px solid #a3bd04!important;border-radius:18px;margin:18px 0}.wce-not-recommended{background:#fff;border:1px solid #e4e4e5!important;border-left:5px solid #c8a24a!important;border-radius:16px;margin:18px 0}.wce-table-wrap{width:100%;overflow-x:auto;border-radius:14px;border:1px solid #e4e4e5;margin:16px 0 4px}.wce-product-page table{width:100%;border-collapse:collapse;background:#fff}.wce-product-page thead th{background:#300b05;color:#fff;text-align:left;font-size:12px;letter-spacing:.04em;text-transform:uppercase;padding:14px 18px}.wce-product-page tbody th,.wce-product-page td{padding:14px 18px;border-bottom:1px solid #e4e4e5;font-size:14px;vertical-align:top;text-align:left}.wce-product-page tbody th{color:#300b05;width:36%;font-weight:700;border-right:1px solid #e4e4e5}.wce-product-page tbody tr:nth-child(odd){background:#f6f6f7}.wce-product-page tr:last-child td,.wce-product-page tr:last-child th{border-bottom:none}.wce-key-benefits h3,.wce-buyer-fit h3,.wce-duct-requirements h3,.wce-register-requirements h3,.wce-airflow-planning h3,.wce-insulation h3,.wce-installation h3,.wce-included h3,.wce-maintenance h3{padding-left:14px;border-left:4px solid #a3bd04}.wce-product-page ul,.wce-product-page ol{margin:10px 0 16px;padding-left:22px}.wce-product-page li{margin:7px 0}.wce-resources ul{list-style:none;padding:0;margin:18px 0 0;display:grid;grid-template-columns:1fr 1fr;gap:10px}.wce-resources li{margin:0}.wce-resources a{display:flex;align-items:center;min-height:58px;background:#fff;border:1px solid #e4e4e5;border-radius:10px;padding:13px 16px;color:#300b05;text-decoration:none;font-weight:700;font-size:14px}.wce-resources a:before{content:\"↓\";display:inline-flex;align-items:center;justify-content:center;width:34px;height:34px;margin-right:12px;border-radius:9px;background:#300b05;color:#c8a24a;font-size:18px;flex:none}.wce-resources a:hover{transform:translateY(-1px);box-shadow:0 7px 18px rgba(48,11,5,.10)}.wce-faq-item{background:#fff;border:1px solid #e4e4e5;border-radius:14px;margin-bottom:10px;overflow:hidden}.wce-faq-item summary{cursor:pointer;list-style:none;padding:16px 52px 16px 20px;font-weight:700;color:#300b05;position:relative;background:#f6f6f7}.wce-faq-item summary::-webkit-details-marker{display:none}.wce-faq-item summary:after{content:\"+\";position:absolute;right:18px;top:50%;transform:translateY(-50%);width:26px;height:26px;line-height:26px;text-align:center;border-radius:50%;background:#300b05;color:#fff}.wce-faq-item[open] summary{background:#300b05;color:#fff}.wce-faq-item[open] summary:after{content:\"−\";background:#c8a24a;color:#300b05}.wce-faq-body{padding:16px 20px}.wce-faq-body p{margin:0}.wce-final-guidance{background:#300b05!important;color:#fff;border-radius:18px;margin:18px 0 0;position:relative;overflow:hidden;text-align:center;padding:42px!important}.wce-final-guidance:before{content:\"\";position:absolute;left:0;top:0;width:100%;height:6px;background:linear-gradient(90deg,#c8a24a,#a3bd04,#c8a24a)}.wce-final-guidance .wce-eyebrow{background:#c8a24a;color:#300b05}.wce-final-guidance h2{color:#fff}.wce-final-guidance p{color:#e8cf93;max-width:820px;margin:0 auto 14px}.wce-product-page a{color:#5a1a0e}.wce-product-page strong{color:#300b05}@media(max-width:860px){.wce-stats{grid-template-columns:1fr 1fr}.wce-resources ul{grid-template-columns:1fr}.wce-product-page\u003esection,.wce-product-header{padding:28px 22px}}@media(max-width:560px){.wce-stats{grid-template-columns:1fr}.wce-product-page h1{font-size:27px}.wce-product-page h2{font-size:24px}.wce-product-page tbody th,.wce-product-page td{padding:12px 13px}.wce-final-guidance{padding:34px 20px!important}}\n\u003c\/style\u003e","brand":"WhisperKOOL","offers":[{"title":"Default Title","offer_id":52126040752348,"sku":"03-DUCTED-KIT-MIN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/WhisperKOOLMiniDuctedAirflowKitwith2DuctPlenums_03-DUCTED-KIT-MIN.webp?v=1785323548","url":"https:\/\/winecoolersempire.com\/products\/whisperkool-mini-ducted-airflow-kit-2-duct-plenums-03-ducted-kit-min","provider":"Wine Coolers Empire","version":"1.0","type":"link"}